Danby DPAC 9009 manual Installation, Window Kit, Air Conditioning Mode ONLY

Models: DPAC 9009

1 26
Download 26 pages 43.48 Kb
Page 6
Image 6
INSTALLATION

 

INSTALLATION

INSTALLATION

ELECTRIC SHOCK HAZARD: To avoid the possibility of personal

 

injury, disconnect power to the unit before installing or servicing.

Flexible Exhaust Hose (13cm) & Exhaust nozzle connector (2 pcs)... from 17 7/10” (45cm) up to 53 1/6” (135cm)

Flexible Exhaust Hose (11cm) & Exhaust nozzle connector (2pcs)...from 15 3/4” (40cm) up to 51 1/5” (130cm)

Ajustable window door slider kit (3 pcs).....

from 28 1/3”(72cm) up to 80” (203cm) Fixture..... (2 pcs)

Screws......(12 pcs)

NOTE: The exhaust/window kit must be installed at all times when the unit is operating under AIR CONDITIONING mode.

There should be at least 11.8” (30cm) clearance between the unit and any other objects or building structures, and should be installed on a level surface. The unit does not have to be vented outside during Dehumidifying or Fan Only mode operation.

Fig. 1 INSTALLATION ACCESSORIES

Exhaust Nozzle Flexible Exhaust Hose Fixture Connector

Screws

Adjustable Window Slider Kit: 28 1/3” (72cm)- 80” (203cm)

Instructions for Assembling the Window Adapter Kit- Fig. 2

1)Insert tube adapters through the back of the window panel.

2)Secure each tube adapter with four screws through the front of the window panel.

3)Insert window panel extensions into window panel. Lightly tighten the screws in the window panel to hold the extensions in place.

Fig. 2

 

Back of Window Pane

 

 

 

Tube Adapters

WINDOW KIT

Air Conditioning Mode ONLY

Your window kit has been designed to fit most standard “vertical”/”horizontal” windows up to a maximum height of 80” (203cm). For vertical window applications, multi lock positions are provided on the edge of each slider section to secure each sliding section together.

1)Select a suitable location, making sure you have access to an electrical outlet.

2)Install the flexible hose to the rear side of the unit. Insert the hose collar on top of the exhaust opening and twist to lock into position.

3)Install the adjustable Window Slider Kit as required (see Fig. 3a & 3b).

4)Install the opposite end of the flexible exhaust hose into the window exhaust adapter.

5)Install the window exhaust adapter into the opening in the slider section, making sure the window slider sections are secure.

6)Plug the unit into a 115V/60Hz grounded electrical outlet.

Fig. 3a

Fig. 3b

Horizontal Window

Window Slider Kit:

 

Min.: 28 1/3(72cm)

 

Max.: 80” (203cm)

 

Vertical

 

Window

Window Slider Kit:

 

Min.: 28 1/3(67.5cm)

 

Max.: 80” (203cm)

 

 

5

Page 6
Image 6
Danby DPAC 9009 manual Installation, Window Kit, Air Conditioning Mode ONLY