INSTALLATION  2 
2.  Release the buttons. 
3.  Press the left button corresponding to the GET function, the center button 
corresponding to the TEST function or the right button corresponding to the 
SEND function. 
NOTE 
Once the buttons are released in step 1, a ten-second timeout starts. 
If no button is pressed within this time (no function is selected), the 
procedure will be cancelled. 
The C-Box 150 warning LED will turn OFF at the end of each 
procedure. 
Function Description 
GET (left button) 
The C-BOX 150 reads the current scanner configuration 
and permanently copies it in its own memory support. 
The C-BOX 150 preserves this configuration also when 
switched off. The GET option can be disabled through 
WinHost. 
TEST (center button) 
The C-BOX 150 forces the WinHost™ compatible scanners 
only to run the Test Operating Mode (refer to the scanner 
Reference Manual for details). 
Press any button to quit the Test Operating Mode and 
restore the scanner normal operating mode. 
For Genius™ compatible scanners you should use the 
scanner keypad. 
SEND (right button) 
The C-BOX 150 sends the configuration previously stored 
in its own permanent memory support to the scanner’s 
memory. 
The SEND option can be disabled through WinHost; by 
default it is Automatic. 
NOTE 
To override the eventual default Automatic SEND service, it is possible 
to preset a GET service by executing the enabling procedure 
immediately at power-on. 
 17