C-BOX 300/310
2
The C-BOX 3X0 spring clamp connector pinouts are indicated in the following table.
Refer to the scanner Installation Manual for details.
Pin Name
1, 3, 5 VS
2, 4, 6 GND
7, 8 EARTH GROUND
9…12, 20, 33, 34, 40 Reserved
35 TXA
37 RXA
DS2100A
DS2400A DS4600A Matrix-2000™ Matrix-1000™
21 OUT1+ OUT1+ OUT1+ NC
22 OUT REF OUT1- OUT1- NC
23 OUT2+ OUT2+ OUT2+ NC
24 OUT REF OUT2- OUT2- NC
25 NC Reserved OUT3+ OUT3+
26 NC Reserved OUT3- OUT3-
27 EXT TRIG+ EXT TRIG+ EXT TRIG A EXT TRIG A
28 EXT TRIG- EXT TRIG- EXT TRIG B EXT TRIG B
29 NC IN1+ IN 2A NC
30 NC IN1- IN 2B NC
31 NC IN2+ NC NC
32 NC IN2- NC NC
36 RTSA GND NC NC
38 CTSA SGND AUX GND GND
39 SGND SGND GND GND
NOTE
Pin 7 or 8 should be connected to the earth ground.
Pins 13… 19 are not present in the C-BOX 3X0 models.
10