INSTALLATION  2 
9-pin external female connector pinout 
Pin Name  Function 
1 N.C.  not connected 
2 N.C.  not connected 
3 B-LINE  (RS485+) 
4 RTS  Ready To Send 
5  GND  RS485 Bus Reference 
6  + 5V (galvanically isolated)  RS485 Bus Power Supply 
7 N.C.  not connected 
8 A-Line  (RS485-) 
9 N.C.  not connected 
The following figure shows a Profibus layout with C-BOX 3X0 devices connected to a 
Profibus Master: 
Profibus DP
Slave node #1
PROFIBUS DP
Master
Profibus DP
Slave node #2
Profibus DP
Slave node #n
C-BOX 3X0
Figure 12 - Profibus Connection 
It is recommended to use only commercially available PROFIBUS connectors for 
connecting to the bus. Use connectors from ERNI and Siemens. If the C-BOX is 
installed at the beginning or end of the PROFIBUS cable segment, it is 
recommended to use PROFIBUS connectors, which contain an integrated 
terminating resistor. 
 13