Datalogic Scanning F732 user manual Troubleshooting, Problem, Cause, Remedy

Models: F732

1 41
Download 41 pages 19 Kb
Page 35
Image 35
6 TROUBLESHOOTING

TROUBLESHOOTING

6

 

6 TROUBLESHOOTING

PROBLEM

CAUSE

REMEDY

When the

Flat batteries.

Recharge

<SCAN> button

 

terminal.

is pressed the

Batteries

Replace

terminal does not

completely flat or

batteries.

come on.

broken.

 

 

 

When the

Flat batteries.

Recharge

<SCAN> button

 

terminal.

is pressed, the

 

 

terminal display s

 

 

Batteries

Replace

the message

completely flat or

batteries.

BATTERY LOW and

broken.

 

switches itself off.

 

 

There is no power

Connect the

 

supply to the

power supply and

The terminal will

cradle.

switch on the

not load the

 

cradle.

application

The serial cable is

Check the

program.

not correctly

connection to the

 

 

connected.

cradle and the

 

 

serial port of the

 

 

computer.

Ed.: 06/01