STARModem™ 
12 
UK/US 
STAR
Modem™ DEFAULT CONFIGURATION RS232 DEFAULT SETTINGS 
9600 baud, parity disabled, 8 data bits, 1 stop bit, handshaking disabled, ACK/NACK 
protocol disabled, inter-character delay disabled, 5 sec. rx timeout, FIFO enabled, 
frame packing = frame + [CR]. 
PEN EMULATION DEFAULT SETTINGS 
Interpret operating mode, minimum output pulse 600 µs, conversion to Code 39, 
overflow medium, output level normal, idle level normal, inter-block delay disabled. 
WEDGE DEFAULT SETTINGS 
USA keyboard, caps lock off, num lock unchanged, inter-character and intercode 
delay disabled, control character emulation = Ctrl + Shift + Key. 
DATA FORMAT 
Code identifier disabled, no header, terminator: RS232 = CR-LF; WEDGE = ENTER, 
header position = first frame field, code length tx not transmitted, address stamping 
disabled, address delimiter disabled. 
RADIO PARAMETERS 
Transmission mode 1 way, radio protocol timeout 2 sec., single store disabled, 
ACK/NACK from remote host disabled, RF baud rate 19200 (European models), 
fixed RF baud rate 36800 (USA model), beacon disabled. 
Datalogic warranties this product against defects in workmanship and materials, for a 
period of 24 months from the date of shipment, provided that the product is operated 
under normal and proper conditions. 
Datalogic has the faculty to repair or replace the product, these provisions do not 
prolong the original warranty term. 
The warranty does not apply to any product that has been subject to misuse, 
accidental damage, unauthorized repair or tampering.