Electrical Considerations
8Pegaso™ Powered Mobile Dock
Electrical System Connections
This section covers electrical connection to +12V, +24V, +36V and +48V sys-
tems.

Connection to +12V

Figure 4 illustrates a typical wiring connection for a +12 volt system. The
input voltage operating range of the dock will allow direct connection to the
battery terminals. However, the use of a 5-Amp fuse is required, and a Noise
Spike/RF filter is highly recommended.
Accessory equipment may also be required depending on your application,
Refer to Table1 on page 2-7. Read and follow all manufacturer's installation
instructions carefully.
Figure 4. Wiring Diagram for +12V Systems
CAUTION
Proper installation requires that source power connections be made directly
to the mobile platform’s positive and negative battery terminals. It is
important to maintain electrical isolation when installing the Powered
Mobile Dock and any accessory equipment, to ensure safe and proper
operation. Do not make any electrical connections directly to the chassis of
the forklift.
Noise/Spike Filter
(Recommended)
DC Conditioner/UPS
(Optional)
Delay Timer
(Optional)*
Use crimp connectors
for all wire connections
Dock
Power Cord
Red (Pos)
Black (Neg)
Pos
+
Neg
-
5-Amp In-Line Fuse
(Required)
ENSURE that the device being
installed is properly rated for use
on your mobile platform.
*
Fuse each device according to
manufacturer’s recommendation