3.PRINT SPECIFICATIONS / REGISTRATION REQUIREMENTS

Media Width:

1.0" (25mm) min. to 4.5" (114mm)

 

max. on 200MVP or 300MVP

Inter-Label Gap

0.08" (2mm) to 0.16" (4mm)

(Distance between labels):

(0.10" -.125” 2.5mm- 3.2mm

 

Recommended)

First Dot Location:

0.10" (2.5mm, not to exceed

 

–0.5/+1.0mm) from inside edge of the

 

media ±0.04mm

Vertical Registration Drift:

Not to exceed ± 0.0393" (1.0mm)

Horizontal Registration

Not to exceed ±0.0591" (1.5mm)

Drift:

 

Longitudinal Drift

± 0.0393" (1.0mm) (with respect to

 

media type) (between any two labels

 

printed from the same label roll)

Variation

(from leading label edge to marking):

 

0.0393" (1mm)

Media Thickness

0.0023" (0.058mm) to 0.010"

 

(0.25mm); die-cut labels, tickets and

 

tags. 2.3 mils to 12 mils

Label Roll Size:

8.0" (203mm) O.D. max. / 3.0"

 

(76mm) I.D. min.

Tear-Off Bar:

Standard

Ribbon Orientation:

Ink Side Out

4.USER INTERFACE CONTROLS AND INDICATOR LIGHTS

A MVP series printer is equipped with a standard LCD control panel for easy user interface and operation. A 2-line, 16 character backlit display and tactile feel buttons on the printer’s front panel enable users to fine-tune and control their print settings, whenever needed, in dim or bright light from any angle. The user can quickly make adjustments and configure the printer to meet the specific needs of the application. Such adjustments can also be accomplished without having to access a computer or software. The drawing of the MVP series front panel (below) depicts the positioning of the indicator lights on the 200MVP/300MVP.

The LCD display is used in configuring the printer; selecting reports to be printed by the Brady printer which identify available fonts, bar code symbologies, images or formats stored in the printer; or a complete record of the printer’s configuration settings; and diagnostic tests or security passwords. The LCD display is also helpful in specifying error conditions and communicating to the operator when the condition has been corrected.

MVP Series Product Guide

- 6 -

Printer Overview

Page 6
Image 6
Datamax 300MVP, 200MVP manual Print Specifications / Registration Requirements, User Interface Controls and Indicator Lights