Dynamic Load Response and Switching Frequency

DATEL has performed extensive evaluations, under assorted capacitive-load conditions, of the dynamic-load capabilities (i.e., the transient or step response) of USQ Series DC/DC Converters. In particular, we have evalu- ated devices using the output capacitive-load conditions we use for our routine production testing (10µF tantalums in parallel with 1µF ceramics), as well as the load conditions many of our competitors use (220µF tantalums in parallel with 1µF ceramics) when specifying the dynamic performance of their devices.

To avoid the added cost of constantly changing test fixtures, we have veri- fied, during our device characterization/verification testing, that 100% testing under the former conditions (the 100µF 1µF load), which we guarantee, correlates extremely well with the latter conditions, for which we and most of our competitors simply list typicals.

If you have any questions about our test methods or would like us to perform additional testing under your specific load conditions, please contact our Applications Engineering Group.

Load Conditions

Performance Specifications

1.2VOUT

1.5VOUT

1.8VOUT

2.5VOUT

3.3VOUT

5VOUT

12 to 24VOUT

 

 

 

 

 

 

 

 

 

 

Load Step = 50 to 75% of IOUT Max.:

 

 

 

 

 

 

 

 

Peak Deviation, typ.

115mV

110mV

125mV

100mV

170mV

125mV

100mV

COUT = 10µF 1µF

Settling Time to ±1% of Final Value, max.

200µs

200µs

225µs

200µs

100µs

100µs

100µs

 

 

 

 

 

 

 

 

Load Step = 75 to 50% of IOUT Max.:

 

 

 

 

 

 

 

10µF 1µF

 

 

 

 

 

 

 

Peak Deviation, typ.

115mV

110mV

125mV

100mV

100mV

125mV

100mV

 

 

Settling Time to ±1% of Final Value, max.

140µs

200µs

225µs

200µs

100µs

100µs

100µs

 

 

 

 

 

 

 

 

 

 

Load Step = 50 to 75% of IOUT Max.:

 

 

 

 

 

 

 

 

Peak Deviation, typ.

120mV

TBD

105mV

90mV

105mV

TBD

85mV

COUT = 220µF 1µF

Settling Time to ±1% of Final Value, typ.

115µs

TBD

170µs

65µs

65µs

TBD

40µs

 

 

 

 

 

 

 

 

Load Step = 75 to 50% of IOUT Max.:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Peak Deviation, typ.

120mV

TBD

90mV

90mV

105mV

TBD

50mV

 

Settling Time to ±1% of Final Value, typ.

150µs

TBD

150µs

70µs

65µs

TBD

25µs

 

 

 

 

 

 

 

 

 

 

Switching Frequency (min./typ./max. kHz)

120/150/180

120/150/180

170/185/200

230/255/280

132/147/162

220/240/260

190/210/230

 

 

 

 

 

 

 

 

 

The listed pair of parallel output capacitors consists of a tantalum in parallel with a multi-layer ceramic.

IO/t = 1A/1µs, VIN = 48V, TC = 25°C.