Dayton 2E510E, 3E219D Pump Rotor, Ignition Control Assembly, Dayton Portable Oil-FiredHeaters

Models: 2E511E 2E510E 3E219D

1 24
Download 24 pages 4.34 Kb
Page 10
Image 10
PUMP ROTOR

Dayton Operating Instructions and Parts Manual

2E510E, 2E511E, 3E218E, and 3E219D

Dayton® Portable

Oil-Fired Heaters

Maintenance (Continued)

PUMP ROTOR

(Procedure if rotor is binding)

1.Remove upper shell (See page 6).

2.Remove filter end cover screws using 5/16" nut-driver (See Figures 24 and 25).

3.Remove filter end cover and air filters.

4.Remove pump plate screws using 5/16" nut-driver.

Blade

Pump Plate

Air Intake Filter

Filter End Cover

Insert

Rotor

Air Output Filter

OTOR-Domestic

PFA/P 056B

Fan GuardIGNITION CONTROL ASSEMBLY

Figure 24 - Rotor Location, Models 2E510E and 2E511E

Blade

Pump Plate

Air Intake Filter

Filter End Cover

Insert

Rotor

OR-Domestic

PFA/P 059A

Air Output Filter

Fan Guard

Figure 25 - Rotor Location, Models 3E218E and 3E219D

5.Remove pump plate.

6.Remove rotor, insert, and blades.

7.Check for debris in pump. If debris is found, blow out with com- pressed air.

8.Install insert and rotor.

9.Check gap on rotor. Adjust to

.003"/.004" if needed (See Figure 26).

Gap Adjusting Screw

Blade

.003"/.004" Gap Measured With Feeler Gauge

Rotor

Gap Adjusting Screw

Figure 26 - Gap Adjusting Screw Locations

NOTE: Rotate rotor one full turn to insure the gap is .003"/.004" at tightest position. Adjust if needed.

10.Install blades, pump plate, air filters, and filter end cover.

11.Replace fan guard and upper shell.

12.Adjust pump pressure (See page 7).

NOTE: If rotor is still binding, proceed as follows.

13.Perform steps 1 through 6 (See page 9, Pump Rotor section).

14.Place fine grade sandpaper (600 grit) on flat surface. Sand rotor lightly in “Figure 8” motion four times (See Figure 27).

15.Reinstall insert and rotor.

16.Perform previous steps 10 through 12.

Sandpaper

Figure 27 - Sanding Rotor

IGNITION CONTROL ASSEMBLY

(PROCEDURE FOR REPLACING FUSE ON MODELS 3E218E AND 3E219D)

High Voltage!

1.Unplug heater.

2.Remove side cover screws (4) using 5/16" nut-driver to expose ignition control assembly.

3.Remove fuse cover.

4.Remove fuse from fuse clips.

5.Replace fuse with fuse of the same type and rating (GMA-10). Do not substitute a fuse with a higher current rating.

6.Replace fuse cover.

7.Replace side cover.

Fuse

Fuse

Clips

Cover

 

Fuse

Figure 28 - Replacing Fuse

104447

10

Page 10
Image 10
Dayton Pump Rotor, Ignition Control Assembly, Dayton Portable Oil-FiredHeaters, 2E510E, 2E511E, 3E218E, and 3E219D