Dayton specifications Models 2E510E, 2E511E, 3E218E, and 3E219D, General Safety Information

Models: 2E511E 2E510E 3E219D

1 24
Download 24 pages 4.34 Kb
Page 3
Image 3
Models 2E510E, 2E511E, 3E218E, and 3E219D

Dayton Operating Instructions and Parts Manual

Models 2E510E, 2E511E, 3E218E, and 3E219D

General Safety Information

Make certain you read and understand all warnings. Keep these instructions for reference. They are your guide to safe and proper operation of this heater.

Safety information appears through- out these instructions. Pay close attention to them. Below are defini- tions for the safety information listed throughout this manual.

Under this heading, installation, operat-

ing and maintenance procedures or practices will be found that, if not carefully followed, WILL result in IMME- DIATE serious personal injury or death.

Under this head- ing, installation,

operating, and maintenance proce- dures or practices will be found that, if not carefully followed, COULD result in severe personal injury or death.

Under this heading, installation, operat-

ing, and maintenance procedures or practices will be found that, if not carefully followed, COULD result in minor personal injury, product or property

IMPORTANT: Every possible circumstance that might involve a hazard cannot be anticipated. The warnings in this manual and on tags or decals affixed to the unit are therefore not all-inclusive. If a procedure, work method, or operating technique not specifically recommended by Dayton is used, you must make sure it is safe for you and others. You should also ensure that equipment will not be damaged or made unsafe by the operat- ing or maintenance method you choose.

Carbon monoxide poisoning may lead

to death! Some people are more affected by carbon monoxide than others. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be operating properly, or the areas may not be sufficiently ventilated. Get fresh air at once! Have heater serviced.

Improper use of this heater can

cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

Make certain you read and understand all warnings. Keep these instructions for reference. They are your guide to safe and proper operation of this heater.

• Use only Kero- sene or No. 1 fuel

oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels.

Fueling

a)Personnel involved with fueling shall be qualified and thoroughly familiar with the manufacturer's instructions and applicable federal, state, and local regulations regard- ing the safe fueling of heating units.

b)Only the type of fuel specified on the heater's data plate shall be used.

c)All flame, including the pilot light, if any, shall be extinguished and the heater allowed to cool, prior to fueling.

d)During fueling, all fuel lines and fuel-line connections shall be inspected for leaks. Any leaks shall be repaired prior to returning the heater to service.

e)At no time shall more than one day's supply of heater fuel be stored inside a building in the vicinity of the heater. Bulk fuel storage shall be outside the structure.

f)All fuel storage shall be located a minimum of 25 feet from heaters, torches, welding equipment, and similar sources of ignition (excep- tion: the fuel reservoir integral with the heater unit).

g)Whenever possible, fuel storage shall be confined to areas where floor penetrations do not permit fuel to drip onto or be ignited by a fire at lower elevation.

h)Fuel storage shall be in accor- dance with the federal, state, or local authority having jurisdiction.

Never use heater where gasoline, paint thinner, or other highly flammable vapors are present.

Follow all local ordinances and codes when using heater.

Use only in well-vented areas. Provide at least three square feet of fresh, outside air for each 100,000 Btu/Hr of rating. This heater produces carbon monoxide, which is listed by the State of California as a reproductive toxin under Proposition 65.

Use only in places free of flammable vapors or high dust content.

Use only with the electrical voltage and frequency specified on model plate.

Use only a three-prong, grounded extension cord.

®

104447

3

Page 3
Image 3
Dayton specifications Models 2E510E, 2E511E, 3E218E, and 3E219D, General Safety Information