Dayton 3WY47, 3WY46 installation instructions AUTO-IDLE Operation, Adjusting the Idle Speed

Models: 3WY46 3WY47

1 40
Download 40 pages 2.5 Kb
Page 15
Image 15

Dayton Operating Instructions and Parts Manual

Models 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46

Operation (Continued)

5.As engine warms up, slowly move choke lever fully to the right (See Figure 28). This opens the choke. On Model 3WY47, the choke will automatically open (See Figure 29).

Choke Lever (Open Position)

Figure 28 – Choke Lever Opened

Choke

Button (Open Position)

AUTO-IDLE OPERATION

IMPORTANT: Never start engine with electrical loads connected. Start engine before adding electrical loads.

1.If engine is cold, turn the auto-idle switch OFF.

2.Start engine. Allow engine to warm up with no load for five minutes.

3.Turn auto-idle switch ON. Engine will slow to idle speed. Engine idle speed is preset. Idle speed adjustment should not be necessary.

4.Operate generator according to specifications outlined in owner's manual.

5.Engine will automatically increase to normal operating speed when you plug load into any generator outlet.

NOTE: The 250 Volt/50 Amp receptacle is not connected through the auto-idle circuit. The auto-idle switch must be turned off to get full power out of this receptacle (See Figure 30).

6.The auto-idle system should be turned OFF when generator is shut down.

 

 

 

Auto-Idle

120 V

 

 

Switch

 

 

OLTS

 

 

 

 

 

RES

 

 

 

 

T

ET

 

 

 

 

 

EST

 

 

 

 

 

120

 

 

 

 

 

ONLY

 

 

 

 

 

 

 

120

 

 

 

 

 

240V

 

 

 

EN

M

 

 

 

 

00

 

 

 

 

0000

 

 

 

 

HOURS

05

RESET

240

 

 

 

1/10

VOLTS

 

 

 

 

 

 

 

 

RESET

 

RESET

 

 

 

 

 

 

 

 

 

 

RESET

ADJUSTING THE IDLE SPEED

IMPORTANT: Adjust the idle speed only:

¥If the idle speed becomes too high.

¥If the engine idle speed will not regulate (engine idles and speeds up again and again).

1.Turn auto-idle switch OFF. Start engine. Allow engine to warm up with no load for five minutes.

2.Remove engine linkage cover (Models 3WY46 and 3WY45 only).

3.Push plunger into solenoid body to manually engage solenoid and set idle speed.

4.Loosen the M8 nut that holds the solenoid mounting bracket to the generator (Models 3WY46 and 3WY45 only, See Figure 31). Do not loosen bolt that holds the solenoid mounting bracket to the generator on Model 3WY47, See Figure 32).

Solenoid

Mounting

Bracket

ENGINE

OFF

M8 Nut

Figure 31 - Solenoid Bracket Location (Models 3WY46 and 3WY45 Only)

Solenoid

Mounting

Bracket

Figure 29– Choke Lever Opened

(Model 3WY47 Only)

Figure 30 - Auto-Idle Switch Location on

Control Panel

Bolt

Figure 32 - Solenoid Bracket Location (Model 3WY47 Only)

®

15

Version B - For Reduction

G016.J

Page 15
Image 15
Dayton 3WY47, 3WY46 installation instructions AUTO-IDLE Operation, Adjusting the Idle Speed