INSTALLATION OF OPTIONAL BLOWER

INSTALLATION OF OPTIONAL BLOWER

Part #831-1700

The blower is shipped fully assembled and ready for installation.

1.Using three 1/4-20 bolts supplied, attach blower to lower rear of stove, as shown.

2.Plug blower cord into a grounded outlet. Do not remove ground prong from plug. Route power cord to avoid heat from the stove, or other damage.

3.Adjust the blower speed control to the desired speed.

BLOWER SWITCH ADJUSTMENTS

The blower speed control for this unit is ad- justed at the factory, and should not require further adjustment. When the speed control is turned clockwise, it will click on to high

FIGURE 21

speed. Turn the speed control clockwise to decrease the speed. At full clockwise, the blower should blow gently, but should not stop.

STEPS FOR ADJUSTING THE BLOWER SPEED CONTROL

1.With the unit plugged in, turn the speed control knob to slow (full clockwise).

2.With a small screwdriver, adjust the blower speed by turning the adjustment mechanism through the hole on the side of the speed control.

3.Adjust the speed so the blower runs slowly, but does not stop. Turn clockwise to slow the blower and counterclockwise to increase the speed.

BLOWER OPERATING INSTRUCTIONS

If your wood stove is equipped with an optional blower, you should follow these guidelines:

1.Initial (cold) start-up: Leave blower off until your stove is hot and a good coalbed is established. The blower may be turned on approximately 30 minutes after loading the stove with fuel.

2.High burn setting: The blower may be left on throughout the burn.

3.Medium burn setting: The blower should be left off until a good burn is established, then turned on at a medium or high rate.

4.Low burn setting: The blower tends to cool off the stove. If you are using wet wood or a very low burn setting, leave blower off until the burn is well established. Then, if you wish, turn the blower on at a lower rate. Too high a blower setting with a low burn rate may adversely affect emissions.

5.The blower is equipped with a speed control. The highest blower speed is obtained by turning the speed control on and then adjusting back towards off as far as possible without turning the blower off. For a low blower speed, turn the control knob clockwise as far as possible.