Dayton 5S1792 Models 2E510F, 2E511F, 3E218F, and 3E219F, Troubleshooting Chart Continued

Models: 5S1792

1 24
Download 24 pages 156 b
Page 23
Image 23
Troubleshooting Chart (Continued)

Dayton Operating Instructions and Parts Manual

Models 2E510F, 2E511F, 3E218F, and 3E219F

Troubleshooting Chart (Continued)

Symptom

Possible Cause(s)

Corrective Action

 

 

 

Heater ignites but ignition control

1. Pump pressure incorrect

1. See Pump Pressure Adjustment,

assembly shuts heater off after a short

 

 

 

page 7

period of time

2. Dirty air intake, air output, and/or

2. See Air Output, Air Intake, and Lint

 

lint filter

Filters, page 6

 

3. Dirty fuel filter

3. See Fuel Filter, page 7

 

4. Obstruction in nozzle assembly

4. See Nozzle, page 9

 

5. Photocell assembly not properly

5. Make sure photocell boot is prop-

 

installed (not seeing the flame)

erly seated in bracket

 

 

 

High Voltage!

 

 

 

 

 

 

 

 

 

 

 

 

 

6. Clean photocell lens

 

6. Dirty photocell lens

 

7. Bad electrical connection between

7. Check electrical connections. See

 

photocell and ignition control

Wiring Diagram, page 21

 

assembly

 

 

8. Defective photocell

8. Replace photocell

 

9. Defective ignition control assembly

9. Replace ignition control assembly

®

111166-01A

23

Page 23
Image 23
Dayton 5S1792 specifications Models 2E510F, 2E511F, 3E218F, and 3E219F, Troubleshooting Chart Continued