Dayton Operating Instructions and Parts Manual

Models 2E510F, 2E511F, 3E218F, and 3E219F

Maintenance (Continued)

NOZZLE

1.Remove upper shell (See page 6).

2.Remove fan (See page 6).

3.Remove fuel and air line hoses from nozzle assembly (See Figure 18 or 19).

4.Turn nozzle assembly 1/4 turn to left and pull toward motor to remove (See Figure 20).

5.Place plastic hex-body into vise and lightly tighten.

6.Carefully remove nozzle from the nozzle adapter using 5/8" socket wrench.

7.Blow compressed air through face of nozzle. This will free any dirt in nozzle area.

8.Inspect nozzle sleeve for damage.

9.Replace nozzle into nozzle adapter until nozzle seats. Tighten 1/3 turn more using 5/8" socket wrench (40- 45 inch-pounds).

Burner Strap

Nozzle

Assembly

Figure 20 - Removing Nozzle Assembly, All Models

10.Attach nozzle assembly to burner strap.

11.Attach fuel and airline hoses to nozzle adapter assembly (see Fuel and Air Line Replacement and Proper Routing).

12.Replace fan (See page 6).

13.Replace fan guard and upper shell.

Nozzle Face

Nozzle

Sleeve

Nozzle

Nozzle Adapter

Air Line

Fitting

Fuel Line

Fitting

Figure 21 - Nozzle and Nozzle Adapter, All Models

FUEL AND AIR LINE REPLACEMENT AND PROPER ROUTING

1.Remove upper shell (See page 6).

2.Remove side cover screws using 5/16" nut driver.

3.Remove side cover.

4.Inspect fuel and air line hoses for cracks and/or holes. If fuel line hose is damaged, disconnect from nozzle adapter (See Figure 18 or 19) and from fuel filter (See page 7). If air line hose is damaged, disconnect from nozzle adapter (See Figure 18 or 19) and from barb fitting on pump end cover (See Figure 22).

Pump End Cover Barb Fitting

Barb

 

Fitting

 

Air Hose

 

40/60,000 Btu/Hr

110/155,000

Models

Btu/Hr Model

Figure 22 - Air Hose to Barb Fitting

5.Install new air and/or fuel line. Attach one end of air line hose to barb fitting on pump end cover (See Figure 22) and the other end to nozzle adapter (See Figure 18 or 19). Attach one end of fuel line hose to fuel filter (See page 7) and the other end to nozzle adapter (See Figure 18 or 19).

NOTE: Route hoses as shown in Figure 18 or 19 according to Model. Hoses are not to touch photocell bracket.

6.Replace side cover.

7.Replace upper shell and fan guard (See page 6).

®

111166-01A

9

Page 9
Image 9
Dayton 5S1792 specifications Nozzle, Fuel and AIR Line Replacement and Proper Routing

5S1792 specifications

The Dayton 5S1792 is a high-performance, compact fan designed primarily for industrial applications, known for its efficiency, durability, and versatility. Built by Dayton, a renowned manufacturer of electric motors and associated products, the 5S1792 model stands out in the market due to its thoughtful engineering and innovative features.

One of the main characteristics of the Dayton 5S1792 is its robust construction. The fan's housing is made from high-quality materials that resist corrosion and protect it against the rigors of demanding environments. This durability not only extends the lifespan of the product but also ensures reliable performance over time, making it ideal for various industrial settings, including factories and warehouses.

The Dayton 5S1792 features a powerful motor that provides consistent airflow, crucial for maintaining optimal conditions in workplaces. With a high airflow capability, the fan effectively circulates air, ensuring that spaces remain cool and comfortable, which is vital for worker productivity and equipment efficiency. The fan is also designed to operate quietly, making it suitable for environments where noise levels are a concern.

In terms of technology, the Dayton 5S1792 is engineered with energy efficiency in mind. It employs advanced motor technologies that not only reduce power consumption but also minimize heat generation. This aspect is particularly beneficial for organizations looking to lower their energy costs while maintaining high-performance standards.

The flexibility of the Dayton 5S1792 is another key feature. It is available in various sizes and configurations, allowing users to select the model that best suits their specific needs. Additionally, the fan can be mounted in multiple orientations, making it adaptable to different installation requirements, whether wall-mounted, ceiling-mounted, or on stands.

Maintenance of the Dayton 5S1792 is straightforward, thanks to its user-friendly design. Accessible components facilitate easier cleaning and servicing, which is essential for prolonging the unit's lifespan and ensuring it operates at peak efficiency.

In summary, the Dayton 5S1792 is a standout choice for those seeking a reliable and efficient fan for industrial use. Its robust construction, powerful motor, energy-efficient design, and versatility make it a trusted option for enhancing airflow in various applications. The consideration of maintenance and ease of use further adds to its appeal, establishing it as a valuable investment for any industrial facility.