Dell 6200 SERIES Private Edge VLANs, Example #4 Viewing IP Subnet and MAC-Based Vlan Associations

Models: 6200 SERIES

1 176
Download 176 pages 5.47 Kb
Page 35
Image 35

Example #4: Viewing IP Subnet and MAC-Based VLAN Associations

console#show vlan association mac

MAC Address

VLAN ID

-----------------

-------

00FF.F2A3.8886

10

console#show vlan association subnet

IP Subnet

IP Mask

VLAN ID

 

----------------

----------------

-------

 

192.168.25.0

 

255.255.255.0

10

192.168.1.11

 

255.255.255.255

10

Private Edge VLANs

Use the Private Edge VLAN feature to prevent ports on the switch from forwarding traffic to each other even if they are on the same VLAN.

Protected ports cannot forward traffic to other protected ports in the same group, even if they have the same VLAN membership. Protected ports can forward traffic to unprotected ports.

Unprotected ports can forward traffic to both protected and unprotected ports.

You can also configure groups of protected ports, but unprotected ports are independent and cannot be added to a group. Each group’s configuration consists of a name and a mask of ports. A port can belong to only one set of protected ports, but an unprotected port can be added to a group as a protected port.

The group name is configurable by the network administrator.

Use the switchport protected command to designate a port as protected. Use the show switchport protected command to display a listing of the protected ports.

Switching Configuration

35

Page 35
Image 35
Dell 6200 SERIES manual Private Edge VLANs, Example #4 Viewing IP Subnet and MAC-Based Vlan Associations