Sharp R-24AT Counter Clear, Information With Error Messages, Information For Filter Indicator

Models: R-22AT R-24AT

1 32
Download 32 pages 63.06 Kb
Page 14
Image 14
COUNTER CLEAR

COUNTER CLEAR

Each number of times can be cleared.

* Suppose you want to clear the times of memory 1.

 

Step

Action

Press pad

 

Display

 

 

 

1

Select check mode.

 

 

 

 

 

 

 

CHECK

X 2

 

 

CHECK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Total times used)

 

 

 

 

 

 

 

 

 

 

 

 

2

Press NUMBER pad 1 .

1

 

 

 

 

 

 

 

NUMBER

CHECK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Times memory 1 was used)

 

 

 

 

 

 

 

 

 

 

3

Press SET pad.

SET

 

 

 

 

 

 

NUMBER

CHECK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Cancel check mode.

CHECK

Note: 1. To clear times of manual cooking, press MANUAL/REPEAT pad at Step 2 instead of NUMBER pad. To clear times of EXPRESS DEFROST cooking, press EXPRESS DEFROST pad at Step 2 instead of NUMBER pad.

2. To clear total using times, miss out Step 2.

INFORMATION WITH ERROR MESSAGES

If ERROR messages are displayed, follow the instructions below.

ERROR MESSAGES

 

EE1 EE2 EE3 EE6 EE8 EE0

Please contact your dealer or an authorized service agent because the

EE10 EE16

oven is malfunctioning.

 

 

EE7

Exhaust air temperature is too high. Check that nothing is blocking the

 

vent openings and air intake openings or that room temperature is too

 

hot or that oven cavity is empty during operation. Correct, press STOP/

 

CLEAR pad and try again after a few minutes.

 

 

EE9

Cooking time exceeds the max. time. Press STOP/CLEAR pad and

programme again.

 

 

 

EE17

Magnetron temperture is too high. Press STOP/CLEAR pad and try again

 

after a few minutes.

 

 

INFORMATION FOR FILTER INDICATOR

1.Clean the air intake filter when the FILTER indicator ligfts up. See page 28. The FILTER indicator will light up when the oven has been operated for about 200 hours in total.

2.To cancel FILTER indicator press the START pad. The oven will start to count the operation time automatically again when the FILTER indicator is cancelled.