Error Code Message Information
SEC0031 Message The chassis is open while the power is on.
LCD Message Intrusion detected. Check chassis cover.
Details The chassis is open. System performance may be degraded, and
security may be compromised.
Action Close the chassis. Check system logs.
SEC0033 Message The chassis is open while the power is off.
LCD Message Intrusion detected. Check chassis cover.
Details The chassis was opened while the power was off. System security
may have been compromised.
Action Close the chassis and verify hardware inventory. Check system logs.
SEL0006 Message All event logging is disabled.
Details This message is displayed when all event logging has been disabled
by the user.
Action If unintended, re-enable logging.
SEL0008 Message Log is full.
Details When the event log is full, additional events are not written to the log.
Older events may be overwritten and lost. This message may also
appear if the user disabled event logging.
Action Backup and clear log.
SEL0012 Message Could not create or initialize the system event log.
Details If the system event log fails to initialize, platform status and failure
events are not captured. Some management software do not report
platform exceptions.
Action Reboot the management controller or iDRAC. Cycle system input
power. If problem persists call support.
SEL1204 Message An unknown system hardware failure detected.
LCD Message Unknown system hardware failure.
Details If the system event log failed to initialize, platform status and failure
events are not captured. Some management software do not report
platform exceptions.
139