Dell T610 manual Ssd/Sas, Storage Controllers

Models: T610

1 58
Download 58 pages 35.82 Kb
Page 41
Image 41

Dell™ PowerEdge™ T610 Technical Guidebook

config

type

configs

description

non-mixed

Mixed SAS/ SATA

drives, all

Min 2xSAS+1xSATA

sata or

2.5": Max 2xSAS + 6xSATA

all sas

3.5": Max 2xSAS + 6xSATA

Min

Max

Min

MAX

HDD

HDD

HDD

HDD

 

 

 

 

 

 

 

 

 

 

 

SAS/SATA

 

 

Integrated

 

 

2.5"=3

2.5"=6

8

MSS-X

SAS/SATA No RAID

 

 

(No RAID)

 

 

3.5"=3

3.5"=6

 

 

(SAS 6/iR)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Integrated

 

 

 

 

 

9

MSSR1R1- X

SAS/SATA RAID

 

 

2.5"=2+2

2.5"=2+2

 

1/RAID 1

 

 

3.5"=2+2

3.5"=2+2

 

 

 

 

 

SAS/SATA

 

 

(SAS 6/iR, PERC 6/i)

 

 

 

 

 

 

 

 

 

 

 

(RAID)

 

 

Integrated

 

 

 

 

 

 

 

 

 

 

 

 

10

MSSR1R5-X

SAS/SATA RAID

 

 

2.5"=2+3

2.5"=2+6

 

1/RAID 5

 

 

3.5"=2+3

3.5"=2+6

 

 

 

 

 

 

 

 

(PERC 6/i)

 

 

 

 

 

 

 

 

 

 

 

 

* Minimum of 1 hard drive for PERC6i ; and minimum of 2 for SAS6iR.

config

type

configs

description

non-mixed

Mixed SSD/ SAs

Min 2xSSD+1xSAS

drives, all SSD

2.5": Max 2xSSD + 6xSAS

 

 

Min

Max

Min

MAX

HDD

HDD

HDD

HDD

 

 

 

 

 

 

 

 

 

 

11

MSSR1

Integrated SSD

2.5"=2

2.5"=2

 

N/A

 

RAID 1 (PERC 6/i)

3.5"=N/A

3.5"=N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSD

12

MSSR5

Integrated SSD

2.5"=3

2.5"=

 

N/A

(RAID)

RAID 5 (PERC 6/i)

3.5"=N/A

3.5"=N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

MSSR10

Integrated SSD

2.5"=4

2.5"=8

 

N/A

 

RAID 10 (PERC 6/i)

3.5"=N/A

3.5"=N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Integrated

 

 

 

 

 

SSD/SAS

14

MSSR1R5-X

SSD/SAS RAID

 

 

2.5"=2+3

 

2.5"=2+6

(RAID)

1/RAID 5

 

 

3.5"=N/A

 

3.5"=N/A

 

 

 

 

 

 

 

 

(PERC 6/i)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D. Storage Controllers

I. SAS 6/iR Description

The integrated SAS 6/iR HBA is a half-length expansion card that plugs into a dedicated PCIe x8 storage slot (only wired for x4). It incorporates two four-channel SAS IOCs for connection to SAS/SATA hard disk drives. It is designed in a form factor that will allow the same card to be used in the PowerEdge T610, R710, and R610.

II. PERC 6/i Description

For customers who need a more advanced hardware RAID solution, the PERC 6/i is an option. The PERC 6/i uses the LSI 1078 ROC (RAID on Chip) processor with a PCI Express host interface and DDR2 memory. A battery is also available for backup. For details of that card, see the PERC 6 Hardware Specification.

41

Page 41
Image 41
Dell T610 manual Ssd/Sas, Storage Controllers