DeLonghi DEGH90WF manual CONVERSION PROCEDURE to convert to Natural gas or to ULPG

Models: DEGH90WF

1 28
Download 28 pages 3.96 Kb
Page 11
Image 11
CONVERSION PROCEDURE (to convert to Natural gas or to ULPG)

CONVERSION PROCEDURE (to convert to Natural gas or to ULPG)

REPLACING THE INJECTORS

The conversion procedure must be carried out only by an authorised person.

This appliance is suitable for use with Natural gas or Universal LPG (check the “gas type” sticker attached to the appliance). The nominal gas consumption and injector size details are provided in table at page 10.

To replace the injectors proceed as follows:

Remove pan supports and burners from the cooktop.

Using a spanner, remove the injector J (figs. 6, 7) and replace it with one according to the gas type (see tables - page 10).

Affix to the appliance the warning label stating that the cooktop has been converted for use with Natural gas/ULPG (supplied with the Natural gas/ULPG conversion kit.). A second Natural gas/ULPG conversion label should also be affixed to an adjacent surface along with the duplicate data plate.

IMPORTANT

If the cooktop is suitable for use with Natural gas and must be converted for use with Universal LPG, before connecting to gas main remove the appliance gas regulator and replace with test point adaptor (see fig. 5a, 5b)

If the cooktop is suitable for use with Universal LPG and must be converted for use with Natural gas, before connecting to the gas main remove the appliance test point adaptor and replace with gas regulator (see figs. 5a, 5b).

NOTE:

Gas regulator and test point adaptor are supplied with the appliance (packed with conversion kit)

The burners are designed so that regulation of primary air is not required.

Figure 6

J

Figure 7

J

11

Page 11
Image 11
DeLonghi DEGH90WF manual CONVERSION PROCEDURE to convert to Natural gas or to ULPG, Replacing The Injectors