GAS SUPPLY:

GAS SUPPLY:

The connection must be executed by an authorised person according to the relevant standards.

Before connecting the appliance to the gas main, mount the brass conical adaptor onto the gas inlet pipe, upon which the gasket has been placed (figures 5a-5b). Conical adaptor and gasket are supplied with the appliance (packed with conversion kit for use with Natural gas or Universal LPG).

This appliance is suitable for use with Natural Gas or Universal LPG. (Check the “gas type” sticker attached to the appliance).

For Natural Gas models the gas supply is connected to the pressure regulator which is supplied with the appliance (fig. 5a). Adjust the regulator to obtain a test point pressure of 1 kPa with the two semi-rapid (SR) burners operating at the maximum.

For Universal LPG models the gas supply is connected to the test point adaptor which is supplied with the appliance (fig. 5b) and ensure that the supply pressure is regulated to 2.75 kPa.

Do NOT force the ”elbow“ rotation prior to loosening nut.

Do NOT over tighten the nut at the ”elbow“.

Figure 5a

 

Gas connection for

 

NATURAL GAS

 

Gas inlet pipe

 

Gasket

Test

Brass conical adaptor

point

(Thread tight: use

 

suitable seal)

 

Gas regulator

8

 

Figure 5b

Gas connection for

UNIVERSAL LPG

Gas inlet pipe

Gasket

Brass conical adaptor

(Thread tight: use

suitable seal)

Test point adaptor

Test

point

Page 8