DeLonghi DEGH90WF manual Gas Taps, Correct Positioning Of The Burners

Models: DEGH90WF

1 28
Download 28 pages 3.96 Kb
Page 22
Image 22
GAS TAPS

GAS TAPS

Regular lubrication of the gas taps must only be performed by Authorized person.

If the gas taps are not working properly, call our Customer Service Centre to obtain the nearest Authorized Delonghi Service Agent.

CORRECT POSITIONING OF THE BURNERS

It is very important to check that spreader “F” and cap “C” of the burner (see Figures 16 and 17) are perfectly in place because if they move out of place serious problems could arise.

Make sure that electrode "S" (Fig. 16) is kept clean so that the sparks always strike.

Make sure that probe “T” (fig. 16) next to each burner is kept clean to ensure correct operation of the safety valves.

Both the probe and ignition plug must be very carefully cleaned.

Note: To avoid damage to the electric ignition do not use it when the burners are not in place.

Figure 16

Figure 17

C

F

T

S