electrical connection
ELECTRICAL REQUIREMENTS
•This appliance must be properly installed and grounded by a qualified technician in accordance with the National Electrical Code ANSI/NFPA No.70 (latest edition) and local electrical code requirements. IN CANADA: Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part1 and/or local codes.
•This appliance may be connected by means of permanent “Hard Wiring” or “Power Supply Cord”. Power supply cord is not supplied, but it is available through your local electric supply house.
•The range must be connected to the proper electrical voltage and frequency as spec- ified on the rating plate.
•The range can be connected directly to the fused disconnect (or circuit breaker box) through flexible, armoured or
WARNING
TO AVOID ELECTRICAL SHOCK HAZARD, BEFORE INSTALLING THE APPLIANCE, SWITCH POWER OFF AT THE SERVICE PANEL AND LOCK THE PANEL TO PREVENT THE POWER F R O M B E I N G S W I T C H E D O N ACCIDENTALLY.
ELECTRICAL CONNECTION WITH POWER CORD
Use a
The
ELECTRICAL CONNECTION WITH CONDUIT
Use 1/2” (1.3 cm) trade size
Where local codes do not permit grounding through neutral, use a green 10 AWG cop- per conductor as directed in the
23