Image 24
3-Wire Flat Power Cord Installation

Screws

Fig. 3.1

 

Terminal Block

 

Access Plate

 

Fig. 3.2

Terminal Block

Ground strap

Neutral Wire

Power Wires

Bracket

Flat

Power Cord

Strain Relief

3-Wire Flat Power Cord Installation

(See Figures 3.1 and 3.2)

1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws (Figure 3.1).

2.Insert the Flat Power Cord through the Bracket; then tighten the Flat Power Cord by using the Strain Relief. Allow enough slack to easily attach the cord terminals to the Terminal Block (Figure 3.2).

3.Remove the 3 wire terminal nuts and washers from the Terminal Block.

4.Plug the terminal holes of Flat Power Cord. The Neutral or Ground Wire of the Flat Power Cord must be connected to the neutral terminal located in the center of Terminal Block. The Power Wires must be connected to the outside terminals (Figure 3.2).

5.Plug washers and tighten nuts securely.

6.Assemble the Terminal Block Access Plate (Figure 3.1).