DeLonghi Pac 1000 manual S e l e c t i n g f u n c t i o n s, Air Conditioner, How To Dehumidify

Models: Pac 1000

1 56
Download 56 pages 23.9 Kb
Page 10
Image 10
S e l e c t i n g f u n c t i o n s

5751009900 17-04-2003 15:07 Pagina 10

S e l e c t i n g f u n c t i o n s

AIR CONDITIONER

With the unit turned off, the function selector

11is in the “O” position. To turn the unit on in

air conditioning mode, proceed as follows:

1.Rotate the function selector knob clock- wise:

• Place the large crystal symbol in line with the reference mark to operate the unit in air conditioning mode at maximum fan speed.

Place the small crystal symbol AIR CONDITIONER in line with the reference mark to operate the

unit in air conditioning mode at minimum fan speed.

2.Now set the required temperature by rotating the room thermostat knob.

Note

The temperature is not expressed in degrees. We therefore recommend rotating the room

thermostat knob 15 to the maximum cool position. When room temperature has reached the required level, rotate the ther- mostat knob slowly clockwise until the ther- mostat is activated, turning the unit off. This programs the unit to the precise level of com- fort required which will then be automatically maintained by the thermostat with consider- able energy savings. When regulating the thermostat, the air conditioning function is temporarily interrupted and the unit contin- ues to operate in fan only mode.

HOW TO DEHUMIDIFY

When the appliance is working as an air condi- tioner, it automatically reduces the excess humidity in the air present in the room. This is

eliminated through the exhaust tube 19 .

If only the elimination of the excess humidity in the room is desired without lowering the temperature, simply turn the function selector knob in a clockwise direction until the

HOW TO DEHUMIDIFY symbol is reached. The excess condensed humidity automatically gathers in the tank

8. It is also possible to carry out continuous drainage of the condensed humidity, follow- ing the instructions aside.

DEHUMIDIFICATION ONLY

Position the appliance in the room without inserting the tube; in this way the dehumidi- fied air will exhaust directly into the room.

Note

In the dehumidifying mode, air colder than the room temperature will exhaust from the air exhaust grill. Conversely, air warmer than room temperature will be exhausted from the cou- pling 4 on the back side of the appliance.

TO TURN THE UNIT OFF COMPLETELY, SET THE FUNCTION SELECTOR 11 TO THE “O” POSI- TION AND UNPLUG FROM THE SOCKET.

REMOVING COLLECTED WATER

Condensation will be collected in the removable tank 8 .

It’s also possibe to drain it continuosly.

CONTINUOUS EXTERNAL DRAINING

THIS UNIT EMPLOYS AN EXCLUSIVE CONDEN- SATION RECYCLING SYSTEM TO DISPOSE OF EXCESS MOISTURE. IN NORMAL CONDITIONS, CONDENSATION IS DISPOSED OF AUTOMATI- CALLY. WHEN THE HUMIDITY IS PARTICULARLY HIGH, AN EXCESS OF CONDENSATION MAY

BUILT UP IN THE TANK 8 . WHEN THIS HAP-

PENS, THE INDICATOR LIGHT

 

14

COMES

ON INDICATING THAT THE TANK

SHOULD BE

EMPTIED. WHENEVER CONDITIONS OF HIGH HUMIDITY MAKE THE PROBLEM RECURRENT, YOU MAY DISCHARGE THE EXCESS WATER DIRECTLY INTO A DRAIN, USING THE RUBBER TUBE SUPPLIED. THE TUBE SHOULD BE INSERTED INTO THE HOLE PROVIDED, AFTER HAVING REMOVED THE RUBBER STOPPER. (see figure below).

MAKE SURE THE TANK IS PUT BACK CORRECTLY OTHERWISE THE LIGHT 14 WILL REMAIN ON.

10

Page 10
Image 10
DeLonghi Pac 1000 manual S e l e c t i n g f u n c t i o n s, Air Conditioner, How To Dehumidify, Dehumidification Only