Troubleshooting

5751009900 17-04-2003 15:07 Pagina 14

Troubleshooting

If the unit is not working properly, this may be due to small problems that you can easily resolve yourself. Follow these instructions carefully before contacting your local De’Longhi Authorized Technical Service Center.

PROBLEM

CAUSE

 

SOLUTION

The unit does not

there is no electricity

wait

work

it is not plugged in

plug in

 

the function selector is in the “O” position

• move the selector to the desired

 

the timer pin is in the “0” position or it is not

 

position

 

programmed to operate at that moment

set the timer to the required

 

 

 

mode (see turning on the unit and

 

 

 

programming the timer)

 

 

 

The unit works for

• there is a kink in the outlet tube

• position the outlet tube correctly

only a short time

• the outlet tube is blocked

• check there are no blockages

 

 

 

preventing the discharge of air

 

 

 

to the outside

 

• there are too many twists in the outlet tube

rearrange the tube correctly

 

 

 

(see set up instructions)

 

• the fan is blocked

• contact the Service Center

 

 

 

 

The tank full light is

• the tank is full activating the safety float

empty the tank

on

• the tank is incorrectly positioned

• reposition the tank correctly

The unit works but does not cool the room

• three minutes have not passed since it was

• wait three minutes (safety

 

turned on

 

device)

windows open

close the windows

• a heat source is operating in the room

eliminate heat sources

 

(burner, light, etc.) or there are a lot of peo-

 

 

 

ple

 

 

• the air outlet tube has detached from the

• fit the tube in the coupling

 

coupling

 

 

• thermostat adjusted too high

lower the thermostat

air filters clogged

clean/replace filters

the cooling capacity of the unit is insuffi- cient for the conditions or size of the room

TECHNICAL ASSISTANCE

Keep the list of Technical Service Centers and

identify the one nearest to you.

RECOMMENDED OPERATING CONDITIONS

Room temperature:

69-90°F

 

(21-32 °C)

 

 

Outside temperature:

69-109°F

 

(21-43 °C)

TECHNICAL SPECIFICATION

Power supply

see rating plate

Max. absorbed power

 

in air conditioning

Refrigerating capacity

see rating plate

Number of fan speeds

2

Dimensions of internal unit:

width

18”

height

31,50”

depth

16”

weight

72,8 lbs.