DeLonghi PAC W130E MAX 39 in, MAX100 cm, MIN 14 in, MIN 35 cm, In the window pane, 4.17 in

Models: PAC W130E

1 20
Download 20 pages 51.91 Kb
Page 6
Image 6
MAX 39 in

AIR-CONDITIONING WITH INSTALLATION

If required, your appliance can also be installed semi-perma- nently (Fig. 7).

Proceed as follows:

Drill a 4.17 inche (106 mm) diameter hole respecting the heights shown in fig. 8 and following the indications in figs. 9, 10 and 11.

8

MAX 39 in

MAX100 cm

MIN 14 in

MIN 35 cm

7

11.8 in

30 cm

11.8 in

30 cm

9

4.17 in 106

In the window pane.

Fit the wall flange (S) into the hole.

Fit the air exhaust hose (K) in the housing at the back of the appliance (fig. 1).

Fit the end of the air exhaust hose to the wall flange as shown in fig. 8. When the air exhaust hose is not fitted, the hole can be closed with the flange cap.

Keep the air hose as short and free of curves as possible to avoid bottlenecks.

When installing the air conditioner semi-permanently, you should leave a door slightly open as little as 1/2(1cm) to gua- rantee correct ventilation.

10

In the wooden kickboard

of a French window.

11

In the wall: it is

recommended that you insulate the section of the wall using suitable insulation.

6