Self diagnosis/Troubleshooting
• the air exhaust hose is blocked

Self diagnosis/Troubleshooting

SELF DIAGNOSIS

The appliance has a self diagnosis system to identify a number of malfunctions.

IF THE DISPLAY SHOWS …

…WHAT SHOULD YOU DO?

 

 

 

When the appliance is operating in air conditioning mode, this device pre-

LOW TEMPERATURE

vents the formation of ice.

(frost prevention)

The appliance starts up again automatically when the defrosting process is

 

completed.

 

 

p f PROBE FAILURE

If this alarm appears, contact the service centre.

(The probe is damaged)

 

 

FULL TANK

Empty the internal safety tank, through the drain hoses.

(The tank is full)

(see page 16 “end of season operations”).

 

 

 

TROUBLESHOOTING

 

 

 

 

PROBLEM

 

CAUSE

 

REMEDY

 

 

 

 

 

 

 

The air conditioning

no electricity

restore electricity

 

unit does not start

it is not plugged into the socket

• plug into the socket

 

 

• the safety device has tripped

reset the safaty plug ( see pag. 17)

The air conditioning • the air exhaust hose has a constriction unit works for a

short time only

position the exhaust hose cor- rectly

check there are no obstacles obstructing air discharge

 

there are tight bends in the air exhaust hose

• eliminate the tight bends

 

 

 

 

 

 

 

The air conditioning

window open

• close the window

unit works, but does

there are heat sources in the room (burner,

• eliminate the heat source

not cool the room

 

lamp, etc)

 

 

the exhaust hose is detached

• connect the exhaust hose

 

air filters clogged

• clean or replace the filters

• Inadequate size of the room (too large)

Particular odour in

air filter clogged

• clean or replace the filter

the room

 

 

 

 

 

 

 

The air conditioning

it is normal for the compressor to start after

• wait for three minutes

unit does not ope-

 

three minutes

 

rate for about three

 

 

 

 

 

minutes after turning

 

 

 

it on.

 

 

 

 

 

 

 

/ PF/ appears

See "self-diagnosis" section

 