SAINT
Keyword 2000 to
01/20/04
Page 9 of 20
4.3.2Gateway Reports
The gateway will report a Reset whenever one occurs. Most likely causes of reset are power on reset, host commanded reset, or gateway micro watchdog error. The gateway does a cold start on all resets (all information is lost). The gateway will also report error conditions with the Report Error message below. See section 4.3.2.1 for error code definitions.
The gateway will also echo back all system commands.
Header | ID | Description | Data Bytes |
|
|
|
|
08h | 80h | Reset Occurred | None |
|
|
|
|
08h | 82h | Report Error | 1 byte Error Code |
|
|
|
|
08h | 86h | Report Time Stamp Information OFF | None |
|
|
|
|
08h | 87h | Report Time Stamp Information ON | None |
|
|
|
|
08h | 88h | Report Transmit Echo ON | None |
|
|
|
|
08h | F0h | Report Gateway Trigger ON | None |
|
|
|
|
08h | F1h | Report Gateway Trigger OFF | None |
|
|
|
|
4.3.2.1Gateway Error Codes
Most error codes are related to sending data at the wrong rate (usually too fast).
Code | Description |
|
|
80h | System - Invalid message ID |
|
|
81h | System - |
|
|
82h | System - UART Error (Overrun, etc.) |
|
|
83h | System – Received message is too long. |
|
|
84h | System - Have not read previous message |
|
|