Delphi manual Page 9 of, 4.3.2Gateway Reports, Saint, Keyword 2000 to RS-232Gateway, 01/20/04

Models: Gateway Systems Analysis INterface Tool (SAINT) RS-232

1 20
Download 20 pages 57.39 Kb
Page 10
Image 10
Page 9 of 20

SAINT

Keyword 2000 to RS-232 Gateway

01/20/04

Page 9 of 20

4.3.2Gateway Reports

The gateway will report a Reset whenever one occurs. Most likely causes of reset are power on reset, host commanded reset, or gateway micro watchdog error. The gateway does a cold start on all resets (all information is lost). The gateway will also report error conditions with the Report Error message below. See section 4.3.2.1 for error code definitions.

The gateway will also echo back all system commands.

Header

ID

Description

Data Bytes

 

 

 

 

08h

80h

Reset Occurred

None

 

 

 

 

08h

82h

Report Error

1 byte Error Code

 

 

 

 

08h

86h

Report Time Stamp Information OFF

None

 

 

 

 

08h

87h

Report Time Stamp Information ON

None

 

 

 

 

08h

88h

Report Transmit Echo ON

None

 

 

 

 

08h

F0h

Report Gateway Trigger ON

None

 

 

 

 

08h

F1h

Report Gateway Trigger OFF

None

 

 

 

 

4.3.2.1Gateway Error Codes

Most error codes are related to sending data at the wrong rate (usually too fast).

Code

Description

 

 

80h

System - Invalid message ID

 

 

81h

System - RS-232 Transmit Buffer Full

 

 

82h

System - UART Error (Overrun, etc.)

 

 

83h

System – Received message is too long.

 

 

84h

System - Have not read previous message

 

 