TABLE OF CONTENTS
SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PAGE SAFETY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 OPERATOR FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 SAFETY FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
INSTALLATION
1 OPERATOR ASSEMBLY. . . . . . . . . . . . . . . . . . . . . . . . . .
ADJUSTMENTS
6 LIMIT SWITCHES & FORCE ADJUSTMENT . . . . . . . . .
7 PROGRAMMING REMOTE CONTROLS. . . . . . . . . . . . . . . 21 8 BATTERY/VISOR CLIP INSTALLATION . . . . . . . . . . . . . . . 22 9 LIGHT BULB AND LENS INSTALLATION . . . . . . . . . . . . . . 22 SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
MAINTENANCE & TROUBLESHOOTING
10 ROUTINE MONTHLY MAINTENANCE . . . . . . . . . . . . . . . . 23 WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 TROUBLESHOOTING GUIDE - OPERATOR . . . . . . . . . . . 25 TROUBLESHOOTING GUIDE - POWER HEAD LED . . . . . 26
TRANSMITTER COMPLIANCY STATEMENT. . . . . . . . . . . . . . . . 27 WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
*Operator MUST be installed with the included Wall Control.
**Safety Beam Safety Reverse System MUST be installed to close door.
OPERATOR FEATURES
INTELLICODE® Rolling Code Security System.
An electronic rolling code system that enhances the security of the door operator by continuously changing the access code each time the remote control is used. The door operator responds to each new code only once. An access code copied from a working system and tried again will not control the door operator.
Lighted Wall Button*.
Operates door operator from inside garage.
(Refer to section 3)
and Car2U™ compatible.
Follow the Homelink® or Car2U™ instructions in your car owner’s manual.
SAFETY FEATURES
Safety Beam Non-Contact Reversing System**.
Puts an invisible beam across the door opening. The door stops and reverses to the full open position if anything passes through the beam. Red or green LED indicator lights on the power head provide a self diagnostic code if an operational problem exits. (Refer to Section 10.)
Safe-T-Stop® Timed Reversed System.
Automatically opens a closing door if it fails to close completely within 30 seconds.
Force Guard™ Control.
Features adjustable open and close force settings. For maximum safety, these must be set to the minimum force required to fully open and close the door. (Refer to Section 6.)
Relay Monitoring System.
Automatically stops and reverses a closing door if the closing relay malfunctions.
Watch Dog™ Monitoring System.
Automatically stops and reverses a closing door if the Safety Beam System** has an operational problem.
Automatic Lighting System.
One bulb lighting supplies up to 60 watts of light for safer evening exits and entries. Turns ON when door is activated and automatically turns OFF 3 minutes later.
Manual Emergency Release.
Manually releases door from door operator. Use during a power failure or other emergency to allow manual opening and closing of door.
PN# 3642036212, 8/09/2007 | 3 |
|