3WALL CONTROL INSTALLATION

3WALL CONTROL INSTALLATION

1.Wall Control location.WARNING

Verify there is NO power to the operator before installing wall control wires and wall control.

2a. Wiring (If pre-wired). CAUTION

Staples which are too tight can cut or pinch wires. Cut or pinched wires can cause the wall control to stop working. When using the insulated staples, make sure you fasten them only as tightly as needed to hold the wire snugly.

2b. Wiring (If NOT pre-wired).WARNING

Use of any other wall control can cause the door to operate unexpectedly and the light not to work. Use only the included wall control.

NOTE: For Wall Control, wire and insulated staples locate Bags 6 and 7 from Box 2.

1.Wall Control location.

Wall Control location should be in direct sight of door.

It should be at least five feet (5') above floor to prevent small children from operating door.

It must be away from any moving parts. (You should NOT be able to reach the garage door while standing at wall control.)

Wall Control board screw connections are polarized, (+) positive and (-) negative.

2a. Wiring (If pre-wired).

Locate wall control pre-wired wire ends (Fig. 3-1). (They should be located within the guidelines mentioned above.)

Split and strip ends of wire (Fig. 3-2).

Fasten wire to wall control board screws on back of wall control.

White wire to the + (plus) terminal.

White striped wire to the - (minus) terminal.

2b. Wiring (If NOT pre-wired).

Pick a convenient location for mounting wall control using the guidelines mentioned above. (Fig. 3-1)

Run wire from wall control to power head

(Fig. 3-1).

Split and strip ends of wire (Fig. 3-2).

Fasten wire to control board screws on back of wall control button.

White wire to the + (plus) terminal.

White striped wire to the - (minus) terminal.

FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM

Wire from

power head

to wall control.

Wall control

"Entrapment" warning label

Separate

 

entry door

EXAMPLE ONLY!

 

This is an example of wire routing when NOT pre-wired. Your wire routing may be different.

FIG.3-1 Wall control wire routing

2"

 

or

B

 

1/2"

 

 

 

 

 

 

 

or

W

 

 

 

FIG. 3-2 Splitting and stripping.

14

PN# 3642036212, 8/09/2007

 

Page 14
Image 14
Genie 1024, 1022 Wall Control Installation, Wall Control location, 2a. Wiring If pre-wired, 2b. Wiring If NOT pre-wired