3.Securely fasten wires.
•Securely fasten wires to ceiling and wall using insulated staples provided.
– Use insulated staples.
– Staples should be snug only.
• If rear cover is attached to power head, remove it.
• On power head:
– Route wall control wires through wire guide.
– Split and strip ends of wire (Fig.
– Insert wire into terminal holes and lightly press in the orange locking clips above each terminal hole. (You can use a pencil or small screwdriver to comfortably press in locking clips.) The white wire into #2 terminal hole and striped wire into the #1 terminal hole.
– Confirm wire lock by lightly tugging on the wire. The wire should remain in the terminal hole.
• Do NOT install rear cover yet.
Locking |
|
|
|
|
|
|
|
| ||
| Clips |
|
|
| Terminal |
|
|
|
|
|
|
|
|
|
| Holes |
|
|
|
|
|
6 | 5 | 4 | 3 | 2 | 1 |
|
|
|
|
|
|
|
|
|
| 6 | 5 | 4 | 3 | 2 | 1 |
|
|
|
|
|
|
|
|
| + – | |
|
|
|
|
|
|
|
|
| P | B |
|
|
|
|
| InfaredSensor |
|
|
|
(Power Head With Rear Cover Removed) FIG.
4.Mounting.
• Fasten wall control to wall with 2 screws
(provided) (Fig.
• Remove protective backing from "Entrapment" warning label (Fig.
– Stick label on wall near wall control.
FIG.
FIG.
PN# 3642036212, 8/09/2007 | 15 |
|