Product Application

Industrial Automation BU, Delta Electronics, Inc.

Full torque output at zero-speed. No sudden drops or jerky movements when the braking unit is not working, which ensures safety and system reliability.

Quick dynamic response, no sudden drops or jerky movements

Modular design of force-cooling fan for heat dissipation. The modular design makes it easy for fan cleaning and replacement.

Active Front End Unit

The Delta AFE2000 series is a substitute for traditional heat dissipation methods. It converts regenerative energy into reusable power and feeds it back to the mains, and allows the AC motor drive to operate in four quadrants to decrease power consumption. It provides innovative, clean and efficient energy solutions for a better tomorrow.

Experiment Results

Before using AFE2000

After using AFE2000

VFD110C23A

VFD110C23A + AFE075A23A

電動模式電流

P = 1,800W

P = 7,000W (consumed) - 4,000W (regenerate) = 3,000W

Q = 9,000VAR

Q = 0VAR

S = 10,000VA

S = 7,000consumed- 4,000VAregenerate= 3,000VA

With solid experience and advanced technology, Delta’s IABU offers efficient and reliable solutions and service — we are your most trustworthy partner.

COPYRIGHT © 2008 DELTA ELECTRONICS, INC . ALL RIGHTS RESERVED .

- 3 -

Page 3
Image 3
Delta AFE2000, C2000 Series manual Experiment Results, = 9,000VAR = 0VAR = 10,000VA