Delta Electronics LCP-1250 CWDM Absolute Maximum Ratings, Recommended Operating Conditions, Unit

Models: LCP-1250 CWDM

1 14
Download 14 pages 34.62 Kb
Page 2
Image 2
Absolute Maximum Ratings

Absolute Maximum Ratings

Parameter

Symbol

Min.

Typ.

Max.

Unit

Note

Storage Temperature

Ts

-40

 

85

ºC

 

Supply Voltage

VCC

0

 

5

V

 

Recommended Operating Conditions

Parameter

Symbol

Min.

Typ.

Max.

Unit

Note

Case Operating Temperature

TC

-5

 

70

ºC

1

Supply Voltage

VCC

3.135

 

3.465

V

 

Data Rate

 

 

1250

 

Mbps

 

Note 1: See order information

 

 

 

 

 

 

Electrical Characteristics

(VCC=3.3V ± 5%)

Parameter

Symbol

Min.

Typ.

Max.

Unit

Note

Total Supply Current

 

 

 

360

 

 

LCP-1250D4xxxRB

ICCT

 

 

mA

 

LCP-1250D4xxxRBH

 

 

380

 

 

 

 

 

 

LCP-1250D4xxxRBT

 

 

 

380

 

 

Transmitter

 

 

 

 

 

 

Transmitter Differential Input Voltage

VDT

0.5

 

2.4

V

1

Transmitter Disable Input-High

VDISH

2

 

VCC+0.3

V

 

Transmitter Disable Input-Low

VDISL

Vee

 

0.8

V

 

Transmitter Fault Pull up Resistor

RTX_FAULT

4.7

 

10

kΩ

2

Transmitter Fault Output-High

VTXFH

2

 

VCC+0.3

V

 

Transmitter Fault Output-Low

VTXFL

Vee

 

0.8

V

 

Receiver

 

 

 

 

 

 

Receiver Differential Output Voltage

VDR

0.35

 

2

V

3

Receiver LOS Load

RRXLOS

4.7

 

10

kΩ

2

LOS Output Voltage-High

VLOSH

2

 

VCC+0.3

V

 

LOS Output Voltage-Low

VLOSL

Vee

 

0.8

V

 

Output Data Rise/Fall Time

tr / tf

 

 

260

psec

4

Notes:

1.Internally AC coupled and terminated to 100Ohm differential load.

2.Pull up to VCC on host Board

3.Internally AC coupled, but requires a 100Ohm differential termination at or internal to Serializer/ Deserializer.

4.These are 20%~80% values

2

2008/1/15

 

Rev. 0A

DELTA ELECTRONICS, INC.

www.deltaww.com