Enhanced Digital Diagnostic Interface

Enhanced Digital Diagnostic Interface

The memory map in the following describes an extension to the memory map defined in SFP MSA. The enhanced interface uses the two wire serial bus address 1010001X(A2h) to provide diagnostic

information about the module’s present operating conditions.

 

2 wire address 1010000 X (A0h)

 

0

 

0

Serial ID Defined by SFP MSA

 

55

 

(96 bytes)

56

95

 

95

96

Vender Specific

96

 

119

 

(32 bytes)

 

120

 

 

127

 

127

128

Reserved in SFP MSA

128

 

 

 

(128 bytes)

247

 

 

 

 

248

255

 

255

2 wire address 1010001 X (A2h)

Alarm and Warning Thresholds

(56 bytes)

Cal Constants

(40 bytes)

Real Time Diagnostic Interface (24 bytes)

Vender Specific

User Writable EEPROM

(120 bytes)

Vender Specific

(8 bytes)