STACKABLE CRESCENT CUBER KM-2400SRF3 KM-2400SRH3 SERVICE MANUAL
NUMBER ISSUED DEC. 23 REVISED DEC, 14
Reliability is a beautiful thingTM
Attn HOSHIZAKI Technical Support Department
Phone 1-800-233-1940 Technical Service
Complete and detailed explanation of the problem
HOSHIZAKI AMERICA, INC 618 Highway 74 South Peachtree City, GA
CONTENTS
REMOVAL AND REPLACEMENT OF FAN MOTOR
REMOVAL AND REPLACEMENT OF EVAPORATOR
REMOVAL AND REPLACEMENT OF CONDENSING PRESSURE
REMOVAL AND REPLACEMENT OF THERMISTOR
KM-2400SRF3, KM-2400SRH3 Remote air-cooled, 3 phase
I. SPECIFICATIONS
2. CONDENSING UNIT, URC-24F
SPECIFICATIONS MODEL URC-24F
Water Valve
II. GENERAL INFORMATION 1. CONSTRUCTION
Float SwitchPressure Switch Cleaning Valve Control Box
Evaporator Spray Tube
b CONTROLLER BOARD
Features of Control Products “E” Controller Board
2. CONTROLLER BOARD
a SOLID-STATE CONTROL
6 LED Lights and Audible Alarm Safeties
2 Defrost Timer
3 High Temperature Safety - 127 ± 7F
4 Low Water Safety
Freeze Cycle
1 beep every 3 sec. = High Evaporator Temperature 127 F
1 Minute Fill Cycle
Harvest Cycle
Control Products HOSHIZAKI001 Board
Control Products HOS-001A Board
c SEQUENCE 1st Cycle
IMPORTANT Water Valve opening is limited to 6 minutes
2nd Cycle and after with pump drain
IMPORTANT Water Valve opening is limited to 6 minutes
2nd Cycle and after with no pump drain
d CONTROLS AND ADJUSTMENTS
KM-2400SRF3
KM-2400SRH3
Resistance k Ω
Dip Switch
3 Drain Timer
The Drain Timer is factory-adjusted, and no adjustment is required
SETTING
e CHECKING THE CONTROLLER BOARD
After the 1 minute water supply cycle, the defrost cycle starts
At this point, the unit should start the defrost cycle
1. WATER CIRCUIT AND REFRIGERANT CIRCUIT
III. TECHNICAL INFORMATION
327 ± 21 PSIG
2. WIRING DIAGRAM
High Pressure Switch ACB-2UB09 Cut-out 412 +210 PSIG
Cut-in
3. TIMING CHART
Page
4. PERFORMANCE DATA
REMEDY
IV. SERVICE DIAGNOSIS 1. NO ICE PRODUCTION
PROBLEM
POSSIBLE CAUSE
PROBLEM
POSSIBLE CAUSE
REMEDY
PROBLEM
POSSIBLE CAUSE
REMEDY
REMEDY
2. EVAPORATOR IS FROZEN UP
PROBLEM
POSSIBLE CAUSE
Solenoid Valve, water system
3. LOW ICE PRODUCTION
4. ABNORMAL ICE
5. OTHERS
b EVACUATION AND RECHARGE R-404A
V. REMOVAL AND REPLACEMENT OF COMPONENTS
1. SERVICE FOR REFRIGERANT LINES
a REFRIGERANT RECOVERY
2. BRAZING DANGER
3. REMOVAL AND REPLACEMENT OF COMPRESSOR IMPORTANT
4. REMOVAL AND REPLACEMENT OF DRIER
5. REMOVAL AND REPLACEMENT OF EXPANSION VALVE
6. REMOVAL AND REPLACEMENT OF HOT GAS VALVE AND LINE VALVE
7. REMOVAL AND REPLACEMENT OF EVAPORATOR IMPORTANT
8. REMOVAL AND REPLACEMENT OF CONDENSING PRESSURE REGULATOR C.P.R
9. REMOVAL AND REPLACEMENT OF THERMISTOR CAUTION
10. REMOVAL AND REPLACEMENT OF FAN MOTOR
12. REMOVAL AND REPLACEMENT OF PUMP MOTOR
11. REMOVAL AND REPLACEMENT OF WATER VALVE
15. REMOVAL AND REPLACEMENT OF SPRAY TUBES
1. PREPARING THE ICEMAKER FOR LONG STORAGE
VI. CLEANING AND MAINTENANCE INSTRUCTIONS IMPORTANT
4 Replace the removed parts in their correct positions
2 Drain the Potable Water Tank 1 Turn off the power supply
2 Move the Control Switch to the “OFF” position
5 Remove all ice from the Storage Bin, and clean the Storage Bin
2. CLEANING PROCEDURE
a CLEANING PROCEDURE
22 Move the Control Switch to the “Wash” position
19 Turn on the power supply to fill the Water Tank with water
20 Turn off the power supply after 3 to 5 minutes
21 Remove the Front Panel, and fully open the Cleaning Valve
b SANITIZING PROCEDURE - Following Cleaning Procedure
3. MAINTENANCE