11)Connect the Thermistor leads through the bushing of the Control Box to the K3 Connector on the Controller Board.

Note: Do not cut the leads of the Thermistor while installing it.

12)Replace the Control Box Cover and the panels in their correct positions.

13)Turn on the power supply.

10. REMOVAL AND REPLACEMENT OF FAN MOTOR

Note: When replacing a Fan Motor with defective winding, it is recommended that a new capacitor be installed.

1)Turn off the power supply.

2)Remove the panels.

3)Remove the Junction Box Cover from the remote condenser unit.

4)Remove the closed end connectors from the Fan Motor leads.

5)Remove the Fan Motor Bracket and Fan Motor.

6)Install the new Fan Motor, and replace the removed parts in the reverse order of which they were removed.

7)Replace the panels in their correct positions.

8)Replace the Junction Box Cover in its correct position.

9)Turn on the power supply.

41