Delta Electronics LCP-155A4HSRBx Absolute Maximum Ratings, Recommended Operating Conditions

Models: LCP-155A4HSRBx

1 12
Download 12 pages 56.21 Kb
Page 2
Image 2
Absolute Maximum Ratings

Absolute Maximum Ratings

Parameter

Symbol

Min.

Storage Temperature

Ts

-40

Supply Voltage

VCC

0

Recommended Operating Conditions

Parameter

Symbol

Min.

Case Operating Temperature

 

-5

Commercial

TC

Extended

-10

 

Industrial

 

-40

Supply Voltage

VCC

3.135

Note 1: See order information

Typ.

Max.

Unit

Note

85ºC

5 V

Typ.

Max.

Unit

Note

 

70

ºC

1

 

85

 

 

 

 

85

 

 

 

3.465

V

 

Electrical Characteristics

(VCC=3.135V to 3.465V)

 

 

 

Parameter

Symbol

Min.

Typ.

Total Supply Current

ICCT

 

 

Transmitter

 

 

 

Transmitter Differential Input Voltage

VDT

0.5

 

Transmitter Disable Input-High

VDISH

2

 

Transmitter Disable Input-Low

VDISL

0

 

Transmitter Fault Output-High

VTXFH

2

 

Transmitter Fault Output-Low

VTXFL

0

 

Receiver

 

 

0.7

Receiver Differential Output Voltage

VDR

0.35

LOS Output Voltage-High

VLOSH

2

 

LOS Output Voltage-Low

VLOSL

0

 

Output Data Rise/Fall Time

tr / tf

 

 

Notes:

2.Internally AC coupled and terminated to 100Ohm differential load.

3.Pull up to VCC with a 4.7K – 10K Ohm resistor on host Board

Max.

Unit

Note

300

mA

 

 

 

 

2.4

V

2

VCC+0.3

V

 

0.8V

VCC+0.3

V

3

0.8

V

3

 

 

 

2

V

4

VCC+0.3

V

3

0.8

V

3

2.2

nsec

5

4.Internally AC coupled, but requires a 100 Ohm differential termination at or internal to Serializer/ Deserializer.

5.These are 20%~80% values

2

2007/11/6

 

Rev. 0D

DELTA ELECTRONICS, INC.

www.deltaww.com

Page 2