MAINTENANCE

MAINTENANCE

How to Use the Maintenance Section

Make the preventive maintenance procedures de- scribed beginning on page 11 a regular part of your maintenance schedule to ensure continuing safe opera- tion of the purifier. If any problems occur that are not remedied by routine maintenance, see the FIELD SERVICE GUIDE.

For assistance with problems not covered in this in- struction manual, call the Deltech Product Service De- partment at 302-328-1345. Identify the purifier by the model number and serial number on the data plate at- tached to the side panel.

How to Return Material to Deltech

If the purifier or a component of the purifier must be returned to Deltech, first call your distributor for a re- turn authorization number. Deltech will determine whether the purifier or only a component must be re- turned. Mark the package with the return authorization number and ship freight prepaid to:

Deltech

Product Service Department

344 Churchmans Road

New Castle, DE 19720

Replacement Parts

There are four replaceable cartridges in each purifier: the coalescing filter element, the activated carbon fil- ter, the catalyst vessel and the afterfilter element. Re- placement part numbers and part locations are shown in Figures 5a through 5c. Part numbers are also given on the data plate attached to the side panel.

WARNING

All cartridges must be monitored and re- placed as directed in the Maintenance sec- tion to ensure safe purifier performance.

Use only genuine Deltech replacement parts. Use of unauthorized parts may cause poor purifier performance, illness, injury or death. Deltech bears no responsibility for hazards that result from using Deltech equipment with non-approved parts.

Preventive Maintenance Schedule

Danger Label: Explosion Hazard

Part No. 56DE194A

Danger Label: Parts of Circuit May Be Energized

Part No. 58DE27A

Daily

Check all indicating lights on the front panel.

If any red indicating light illuminates, discon- tinue use of the purifier. Refer to the FIELD SERVICE GUIDE.

When the yellow SERVICE DUE light is on and the System Operation Monitor is in scan mode, the digital display will show “CHG PAR- TICULATE,” when the particulate afterfilter element must be changed, or “CHG SEPARA- TOR” when the prefilter/separator element must be changed. Refer to MAINTENANCE PRO- CEDURES in this manual for detailed instruc- tions on changing the elements.

Check automatic drain valves on coalescing fil- ter. If an automatic drain valve (ADV) is not working properly, liquids will accumulate in the bottom of the filter. Accumulated liquids may cause high pressure drop, short element life, ele- ment failure or reentry of oil and other separated contaminants into the airstream. If no liquid is discharging from the ADV, immediately stop using the purifier as a source of breathing air and follow the procedure for Shutdown. Dis- mantle and clean, repair or replace the drain valve. Refer to Bulletin 138 (included with this