SAFETY

The instruction plate is firmly attached to the purifier for quick reference to important instructions. The plate does not replace the complete manuals supplied with the purifer. Do not remove or deface the plate.

SAFETY

8DM Series purifiers are designed and constructed with safety as a prime consideration. Each purifier is pressure tested to 1½ times its maximum operating pressure.

DANGER

The following safety rules are crucial to en- sure safe purifier operation. Failure to follow these 9 important rules may result in purifier damage, inadequate purification, severe ill- ness, injury or death.

1.Do not allow grossly contaminated air into the pu- rifier inlet. See Table I for maximum allowable in- let carbon monoxide concentration.

2.Do not allow oxygen-deficient air into the purifier inlet. The purifier will not increase the oxygen content of air.

3.Contact Deltech if any unusual contaminants may be in the compressed air. The purifier removes only oil, moisture, particulates and carbon monox- ide.

Danger Label: Grossly Contaminated Air

Part No. 56DE152A

4.Do not operate the purifier at pressures, tempera- tures or flows above the maximum conditions stamped on the data plate attached to the side panel.

5.Do not use the purifier for any gases other than compressed air.

Purifier Data Plate

Part No. 44DE23A

6.Vent purifier internal pressure to the atmosphere before disassembling any purifier parts.

7.Do not readjust the purifier without factory authorization. The purifier is fully adjusted at the factory.

8.Use only genuine Deltech replacement parts, ele- ments and cartridges. Deltech bears no responsi- bility for hazards that result if Deltech equipment is used with non-approved parts.

9.Replace all cartridges according to the preventive maintenance schedule starting on page 13 in this manual.

INSTALLATION

Receiving and Inspection

Immediately on receipt of the purifier, check for dam- age that may have occurred during shipping. If there is any damage, do not install or attempt to repair the pu- rifier. Installation and use of damaged equipment may void the warranty or cause serious injury.

If the purifier is damaged, contact your local distribu- tor. Since the purifier is shipped F.O.B. New Castle, Delaware, the carrier is legally responsible for any damage incurred during shipping. Shipping damage is not covered by the purifier warranty.