New Buck Corporation 81 installation instructions Section Pre-Fabinsert Installation

Models: 81

1 39
Download 39 pages 49.04 Kb
Page 14
Image 14
SECTION III

SECTION III

PRE-FAB INSERT INSTALLATION

The Model 81 may be installed into any UL listed pre-fabricated fireplace that is large enough to accept it.

NOTE: When installing the Model 81 into a Pre-Fab Zero-Clearance fireplace, a UL-1777 LINER must be installed the Full Length of the chimney and attached to the flue exit of the Insert.

NOTE: The ash lip, smoke baffle, and smoke shelf of the pre-fab fireplace may be removed if necessary to provide room for these models. Any other alteration to the unit will void ALL NBC manufacturer's responsibility, liability. The warning label below must be attached to the back of the fireplace.

NOTE: Plug the power cord into a 115V AC outlet. Set switch to “Manual” and rheostat to “High” position to ensure motor operates properly. Route the cord to prevent damage to the cord insulation from heat and sharp objects. Keep the cord out of the way of traffic to prevent damage caused by tripping, etc.

NOTE: DO NOT BLOCK ANY EXISTING LOUVERS OR VENTS ON THE EXISTING PRE-FAB WITH ANY TRIM PANELS FOR THE MODEL 81.

Except for the “NOTES” above, please follow the instruction of masonry installation, Section II.

Instruction

Minimum clearances for stove

Minimum clearances for floor protector

WARNING: This fireplace must be restored to it’s original condition for safe use if the fireplace insert is removed.

12

Page 14
Image 14
New Buck Corporation 81 installation instructions Section Pre-Fabinsert Installation