Danger Label: Parts of Circuit May Be Energized
Part No. 58DE27A
Do not turn power switch to ON until the end of the
3.During the
Warning Label: Switch | Danger Label: Purifier Will |
Must Be On | Not Operate |
Part No. 44DE112A | Part No. 58DE23A |
For all purifier models:
4.Turn the
Do not allow air to flow through the purifier dur- ing the second
When the power switch is turned on, the POWER ON light will light. It is normal for the fans to cy- cle on and off or to run continuously in warm am-
bient air temperatures. It is also normal if some of the red indicating lights flash.
5.After the power switch has been on for one hour, check the control panel. The red indicating lights should signal in sequence. If any red indicating light flashes call the Deltech Product Service De- partment for instructions.
6.Supply compressed air up to the inlet valve.
7.Slowly open the inlet valve and allow the purifier to reach operating pressure. If no pressure gauge is installed in the air line, wait three minutes.
8.Slowly open the outlet valve to let purified air flow downstream.
Once this
Shutdown
8DM Series purifiers are designed to run continuously. Do not turn the purifier off unless maintenance is needed. Restarting the purifier involves a significant
To shut down the purifier:
1.Stop using the outlet air for breathing.
2.Close
3.Turn the power switch on the front panel to OFF.
4.Open
Danger Label: Parts of Circuit May Be Energized
Part No. 58DE27A
10 | Pyramid 8000® Series Purifiers (Bulletin 289) |