ENGLISH

Getting

Step 3 : Calculation

When “Calculate” is selected at “Step 2”, the measurements taken are analyzed automatically

 

Started

to determine how the speaker system interacts with the room.

Step 2 in 5 or less positions, press i to select “Calculate”.

Connections

“Calculate” is displayed when you have completed measurements in 6 positions. To complete

The time required for this analysis depends on the number of speakers connected. The higher

 

 

the number of speakers, the longer the time required for analysis.

 

NOTE

Setup

Do not change the speaker connections or subwoofer volume, or speaker locations after making

 

 

measurements. These types of changes will invalidate the EQ solution provided. If changes

Playback

are necessary, make the changes and use the Audyssey MultEQ Auto Setup once again for an

updated EQ solution.

 

Remote

Step 4 : Check

Once the calculation is completed, a measuring result check (“Parameter Check”) is displayed.

 

Control

Press o to check the result.

Press ui to select the item, then press o.

 

-Multi

Values that are different from the actual distance may be set for speakers with built-in filters

 

Zone

(subwoofers, etc). This is because filters add electrical delay to the signal that should be

compensated.

Information

Step 5 : Store

 

 

The auto setup measurement results are stored in the AVR-1708 or cancelled.

Troubleshooting

After checking, press ENTER to select “Store”, then press ui to select “Store” or “Cancel”.

Do not turn the power off while the settings are being stored.

 

Store

: Press o to store this calibration permanently to memory.

 

Cancel : Press o to cancel this calibration and clear all Auto Setup data measured.

 

NOTE

 

 

 

sError Messages

If the auto setup procedure could not be completed due to speaker installation, the measuring environment, etc. an error message is displayed. Check the relevant items and be sure to take the necessary measures. After addressing any issues, perform the auto setup procedure over again.

 

Error messages (examples)

 

Cause

 

 

 

 

Measures

 

 

 

 

 

• The included setup microphone is not

• Connect

the

included

setup

 

 

 

 

 

Mic or

Sp:NONE

 

connected.

 

 

 

 

microphone to <SETUP MIC>.

 

 

 

 

 

• Not all speakers could be detected.

• Check the speaker connections.

 

 

 

 

 

 

 

 

 

 

• Too much

noise in

the

room

for

• Either turn off any device generating

 

 

 

 

 

Ambient

Noise

 

accurate measurements to be made.

noise or move it away.

 

 

 

 

 

 

 

 

 

 

• Try again when the surroundings are

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

quiter.

 

 

 

 

 

 

 

• Speaker or subwoofer sound is too

• Check the speaker installation and the

 

 

 

 

low for accurate measurements to be

direction in which the speakers are

 

 

 

 

made.

 

 

 

 

facing.

 

 

 

 

 

 

 

 

 

 

 

 

• Adjust the subwoofer’s volume.

 

 

 

 

 

• Displayed

speaker

could

not

be

• Check the

connections of

the

 

 

 

 

 

Caution:Sp None

 

detected.

 

 

 

 

displayed speaker.

 

 

 

 

 

 

· The front L and front R speakers

 

 

 

 

 

 

 

 

 

 

 

 

 

FR

 

 

were not properly detected.

 

 

 

 

 

 

 

 

 

· Only one channel of the surround

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

speakers was detected.

 

 

 

 

 

 

 

 

 

 

· Sound was output from the R

 

 

 

 

 

 

 

 

channel when only one surround

 

 

 

 

 

 

 

 

back speaker was connected.

 

 

 

 

 

 

 

 

 

· The surround back speaker was

 

 

 

 

 

 

 

 

detected, but the surrounds were

 

 

 

 

 

 

 

 

not detected.

 

 

 

 

 

 

 

 

 

 

 

• Displayed

speaker connected

with

• Check the polarities of the displayed

 

 

 

 

 

Caution:Phase

 

the polarities reversed.

 

 

speaker.

 

 

 

 

 

 

 

 

 

 

 

 

• For some

speakers, this

error

 

 

 

 

 

 

 

 

 

 

SBL

 

 

 

 

 

 

 

message may be displayed even if

 

 

 

 

 

 

 

 

 

the speaker is properly connected. If

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

you are sure that the wiring is correct,

 

 

 

 

 

 

 

 

 

select “Skip”.

 

 

Select “Retry” to make the measurements again.

NOTE Be sure to turn the power off before checking speaker connections.