When using a subwoofer, make the following settings before starting the auto setup procedure:

Defeat the volume and crossover controls if possible

If this is not possible then set:

Volume: “12 o’clock” position

Crossover frequency: “Maximum/Highest Frequency”

Low pass filter: “Off”

Standby mode: “Off”

NOTE

Do not disconnect the setup microphone until the auto setup procedure is completed.

When using headphones, unplug the headphones before starting the auto setup procedure.

Auto Setup

Optimize settings for speakers in use.

aAuto Setup

The settings found at this stage are applied automatically.

GAuto setup flowH
Step1: Speaker Detection
Step2: Measurement
Step3: Calculation
Step4: Check
Step5: Store
Start

Press o to start the MultEQ Auto Setup.

The Audyssey MultEQ Auto Setup process automatically calculates the size, level, distance, bass management crossover frequency, and optimal settings for each speaker and subwoofer. Audyssey MultEQ corrects acoustical distortions within the listening area.

Before starting, connect and position all your speakers.

Once started, MultEQ will play a series of test tones through each speaker.

If an error message appears during the measurements, check “Error Messages”, take the advised action, then start the measurements again (vpage 21).

Step 1 : Speaker Detection

The speaker connection and polarity are detected at the first measurement position. The following attributes are also determined at this time: “Speaker Size”, “Speaker Distance”, “Channel Level”, “Crossover Frequency”.

Once the measurements are completed, “Sp Detect Check” is displayed.

Press ENTER to check the results of the speaker detection. Example : 7.1-channel systems

Speaker:3/4/.1

Subwoofer

Surround and Surround back speakers

Front and Center speakers

If the results are not as expected or if an error message is displayed, address any error as required, select “Retry” and perform the measurement again.

If the results of measurement are still not as expected or an error message is displayed, turn off the power switch and check the speaker connections. Then start measurements again from the beginning.

ENGLISH

NOTE

Getting

• Loud test sounds may be played during Audyssey MultEQ Automatic

 

Speaker Setup.This is part of normal operation. If there is background

Started

noise in room, these test signals will increase in volume.

 

• Do not stand between the speakers and setup microphone or allow

 

obstacles in the path while the measurements are being made. This

Connections

will cause inaccurate readings.

 

• Quiet the listening environment before beginning measurements and

 

refrain from talking. Turn off air conditioning units or other devices

 

that emit noise if at all possible as measurements may be affected

 

by these sounds.

 

Setup

the measurements.

• Operating MASTER VOLUME during the measurements will cancel

 

• Do not change the speaker connections or subwoofer volume after

 

Playback

“Step 1”.

 

Step 2 : Measurement

Remote

q Press i to select “2nd Start”, then press o.

• Measures the 2nd measurement position.

w Move the microphone to the 3rd point and press o.

Control

• Measures the 3rd measurement position.

e Perform w repeatedly.

 

• To measure the remaining measurement positions.

Zone-Multi

After completing a measurement position, move the microphone to

the next position.

Information

Measure at 6 positions: the main listening position and 5 other

surrounding positions. Although it is allowable to measure less than 6

positions, it is recommended to measure 6 for best results.

 

 

Troubleshooting

0