CHECKING GAS CONNECTIONS

INSTALLING

Continued

CAUTION

WARNING ICON

G 001

Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.

 

A.G.A. Design-Certified

 

Manual Shutoff Valve

From

With 1/8" NPT Tap*

External Regulator

 

(11" W.C.** to

 

14" W.C.

 

Pressure)

 

Tee Joint

 

Pipe

3" Minimum

Nipple

Cap

 

Sediment

Figure 14 - Gas Connection

Trap

 

Approved Flexible Gas Hose (if allowed by local codes)

Gas

Regulator

18

*Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 29.

**Minimum inlet pressure for purpose of input adjustment.

CHECKING GAS CONNECTIONS

WARNING

WARNING ICON

G 001

Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.

WARNING

WARNING ICON

G 001

Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

CAUTION

WARNING ICON

G 001

Make sure external regulator has been installed between propane supply and heater. See guidelines under Connecting to Gas Sup- ply, page 16.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG

1.Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where manual shutoff valve was connected.

102783