Desa 102783-01B installation manual Operating Heater, Variable Control Operation, Continued

Models: 102783-01B

1 32
Download 32 pages 50.05 Kb
Page 22
Image 22
OPERATING HEATER
C-clockwise
C-clockwise

OPERATING HEATER

Continued

22

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information on page 21. If you don’t smell gas, go to the next step.

5. Slightly depress and turn control knob counterclockwise VARIABLE CONTROL OPERATION to the PILOT position. Keep control knob pressed in for five (5) seconds (see Figure 20, page 21).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not light, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure on page 23.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

Thermocouple

Ignitor Electrode

 

Pilot Burner

Figure 21 - Pilot

8. Slightly depress and turn control knob counterclockwise Manual background to the HIGH position. The burner should light. Set control knob to any heat level between HIGH and LO.

VARIABLE CONTROL OPERATION

The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provides realistic, dancing yellow flames. Selecting higher settings produces greater heat output. This results in increased heating comfort.

WARNING

WARNING ICON

G 001

Do not operate heater between PILOT and HIGH positions.

CAUTION

WARNING ICON

G 001

Do not try to adjust heating levels by using the manual shutoff valve.