Desa 102783-01B installation manual Installing, Continued, Pressure Testing Heater Gas Connections

Models: 102783-01B

1 32
Download 32 pages 50.05 Kb
Page 19
Image 19
Pressure Testing Heater Gas Connections

INSTALLING

3.

Pressurize supply piping system by either using compressed air or

 

opening propane supply tank valve.

 

 

Continued

4.

Check all joints of gas supply piping system. Apply mixture of liquid soap and

 

 

water to gas joints. Bubbles forming show a leak.

 

5.

Correct all leaks at once.

 

6.

Re-connect heater and manual shutoff valve to gas supply. Check re-connected

 

 

fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG

1.Close manual shutoff valve (see Figure 15).

2.Pressurize supply piping system by either using compressed air or opening propane supply tank valve.

3.Check all joints from propane supply tank to manual shutoff valve (see Figure 15). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Pressure Testing Heater Gas Connections

1.Open manual shutoff valve (see Figure 15).

2.Open propane supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from manual shutoff valve to control valve (see Figure 16). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 21 through 23). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 23).

Open

Manual Manual background

Shutoff

Valve

Closed

Figure 15 - Manual Shutoff Valve

Manual

Shutoff

Valve

Propane

Supply Tank

Control Valve Location

Figure 16 - Checking Gas Joints

Continued

19

 

102783

Page 19
Image 19