SERVICE PROCEDURES

SERVICE PROCEDURES

Upper Shell Removal

1.Remove screws along each side of heater using 5/16" nut-driver. These screws attach upper and lower shells together.

2.Lift upper shell off.

3.Remove fan guard.

Fan

IMPORTANT: Remove fan from motor shaft before removing motor from heater. The weight of the motor resting on the fan could damage the fan pitch.

!WARNING

Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.

Upper

 

Upper

 

Shell

Fan

Shell

Fan

 

 

 

 

Guard

 

Guard

 

 

 

 

Figure 7 - Upper Shell Removal,

Figure 8 - Upper Shell Removal,

35/50/55/70,000 BTU/Hr Models

100/110/150,000 BTU/Hr Models

1.

Remove upper shell (see above).

2.

Use 1/8" allen wrench to loosen

 

set-screw which holds fan to motor

 

shaft.

3.

Slip fan off motor shaft.

4.

Clean fan using soft cloth mois-

 

tened with kerosene or solvent.

5.

Dry fan thoroughly.

6.

(35/50/55/70/100,000 BTU/Hr

 

Models) Replace fan on motor

 

shaft. Place fan hub flush with end

 

of motor shaft (see Figure 9).

 

(150,000 BTU/Hr Model) Replace

 

fan on motor shaft. Make sure set

 

screw is touching back of flat

 

surface on motor shaft (see Figure

 

10).

7.

Place setscrew on flat of shaft.

 

Tighten setscrew firmly (40-50

Fan

Motor

Flush

Motor

Shaft

Setscrew

Fan

Back of Flat

Surface on

Motor Shaft

Setscrew

Motor

Shaft

Motor

 

inch-pounds).

8. Replace fan guard and upper shell.

Air Output, Air Intake, and Lint Filters

1.Remove upper shell (see above).

2.Remove filter end cover screws using 5/16" nut-driver.

3.Remove filter end cover.

4.Replace air output and lint filters.

5.Wash or replace air intake filter (see Preventative Maintenance Schedule, page 8).

6.Replace filter end cover.

7.Replace fan guard and upper shell.

IMPORTANT: Do not oil filters.

10

Figure 9 - Fan Cross Section

Figure 10 - Fan Cross Section

35/50/55/70/100/110,000 BTU/Hr Models

150,000 BTU/Hr Model

Air Intake

 

Air Intake

 

Filter

 

Filter

 

Filter End

 

Filter End

Fan Guard

Cover

Fan

Cover

 

 

 

 

Guard

 

 

Lint Filter

Lint Filter

 

Air Output

Air Output

Filter

Filter

Figure 11 - Air Output, Air Intake,

Figure 12 - Air Output, Air Intake,

and Lint Filters, 35/50/55/70,000

and Lint Filters, 100/110/150,000

BTU/Hr Models

BTU/Hr Models

099176

Page 10
Image 10
Desa 110, 35, 000 BTU/Hr ARL, 000 50, 150 Service Procedures, Upper Shell Removal, Air Output, Air Intake, and Lint Filters