Desa 50 owner manual Operation, Continued

Models: 50

1 60
Download 60 pages 23.65 Kb
Page 9
Image 9
OPERATION

OPERATION

Continued

4.Plug heater’s power cord into approved, grounded, three-wire extension cord. Extension cord must be at least six feet (1.8 meters) long.

Extension Cord Size Requirement

6 to 10 feet (1.8 to 3 meters) long, use 18 AWG (0.75 mm2) rated cord

11 to 100 feet (3.3 to 30.5 meters) long, use 16 AWG (1.0 mm2) rated cord 101 to 200 feet (30.8 to 61 meters) long, use 14 AWG (1.5 mm2) rated cord

5.Plug extension cord into standard 120 volt/60 hertz, 3-prong grounded outlet. Heater will start when extension cord is plugged into outlet. If not, push in heater’s safety control reset button (see Figures 6 and 7).

 

Safety

Safety

Control

Control

Reset

Reset

Button

Button

 

Figure 6 - Safety Control Reset

Figure 7 - Safety Control Reset

Button, 35/50/70 Models

Button, 100/150 Models

To Stop Heater

1. Unplug extension cord from outlet.

To Restart Heater

1.Wait two minutes after stopping heater.

2.Repeat steps under To Start Heater.