Desa and 55 owner manual Wiring Diagrams, Ignition Control Assembly, Portable Forced Air Heaters

Models: and 55

1 14
Download 14 pages 59.46 Kb
Page 10
Image 10
WIRING DIAGRAMS

35,000, 50,000, And 55,000 Btu/Hr H.S.I. Series

PORTABLE FORCED AIR HEATERS

WIRING DIAGRAMS

Black

Power Plug 120V/60Hz

Green

White

Ignitor

Gray

Red

Motor Green

White

Blue

Photocell

Blue

Gray

IGNITOR

L1 (120V)

MOTOR MAIN

IGNITOR

Ignition Control

Assembly

MOTOR RETURN

PHOTOCELL

PHOTOCELL

102350

L2 AC NEUTRAL

PART#

 

Figure 17 - Wiring Diagram For Heaters Using 102350-01 Ignition Control Assembly

Ignitor

Gray

Gray

IGNITOR

Red

MOTOR MAIN

Power Plug 120V/60Hz

Motor Green

Ignition Control

Assembly

Green

Black

120V (L1)

 

 

White

AC NEUTRAL (L2)

 

White

MOTOR RETURN

 

 

IGNITOR

Blue

PHOTOCELL

Photocell

PHOTOCELL

Blue

104040

Figure 18 - Wiring Diagram For Heaters Using 104040-02 Ignition Control Assembly

10

102388

Page 10
Image 10